您好,欢迎访问三七文档
1目录一、工程概况·································································2二、编制依据····································································2三、降水方案选择·······························································2四、井点降水相关计算·························································3五、主要降水设备·······························································6六、施工工期·····································································7七、井点施工方法·······························································7八、质量标准及质量保证措施················································8九、危险点分析································································10十、安全生产及文明施工措施···············································10十一、环保措施································································112一、工程地质概况二、编制依据《JGJT111-98建筑与市政降水工程技术规范》《施工图纸及地质勘测报告》三、降水方案选择本工程电梯井基底在-2.7m,基础基底在-2m左右,本工程采取的措施是:采用明沟、集水井的方式进行作业层表面水的降水;采用井点降水,对电梯井基底进行降水。本工程电梯井底标高为-2.7m,可采用井点降水。电梯井基底平面基底尺寸约为2.6m×2m。基础详见施工图,结合本工程基础施工水文条件,采用井点降水法,在电梯井南北或东西两侧各设置一口管井(管井设置以利于基础施工为准)。四、主要降水设备1、本工程共设轻型潜水泵(电梯井个数*2)台,预留3-4台备用泵。2、井点降水井点为(电梯井个数*2)眼井。3、井管:本工程井点管采用直径500mm水泥管,内径400mm,深度为6m(大基础标高下,如直接打井则井深度为6+基础标高)。五、施工工期六、井点施工方法1、施工流程布置井点管井点管与总管连接试抽水进入工作状态基础结束及回填完后拔管。2、井点施工方法(1)、井点管的埋设1)、采用专业打井设备进行打井作业,并埋设井点管。2)、井点管埋设完毕,应接通总管与抽水设备进行试抽水。检查有无漏水,漏气现象,出水是否正常,有无淤塞现象,如有异常情况应及时进行修理。(2)、井点管的使用井点管工作后,应保证连续不断的排水,正常出水规律是“先大后小,先混后清”。如不上水,或水一直较混或出现清后水混等情况,应立即检查纠正。3(3)、井点管的拆除待地下构筑物竣工并进行回填土后,方可拆除井点系统,所留孔洞用砂或土填塞。3、施工要点因本工程基坑面积较大,故采用沿建筑物环状布置井点。井点管布置距电梯井基底距离为1m。降水设施完毕后开始降水,每天定点定时检查水位并进行记录,发现水位异常随时汇报。降水过程中水泵设备设专职人员昼夜进行值班,观测各井点降水情况和各泵运行情况,如下渗水量不满足水泵运行时,及时更换水泵。水位降至设计基层下1m后,进行土方施工。七、质量标准及质量保证措施1、质量标准序号检查项目允许偏差检查方法1井管插入深度(mm)≤200水准仪2井点真空度(kPa)60真空度表3井管间距(mm)≤150用钢尺检查4抽排水含砂量(体积比)1/10000取水样做试验5井管垂直度(%)1插管时目测6降水深度符合设计要求稳定24h2、质量保证措施(1)、坐标及高程控制点经过场区内基准点引测,检查验收合格后进行土方开挖、降水施工。(2)、土方开挖前用石灰划出开挖线,确保土方开挖尺寸正确。基坑开挖尺寸及标高符合质量标准。(3)、为了保证达到有效降水,机械型号、功率须达到方案要求。并现场配有备用泵。(4)、在施工区域设有降水观察孔,掌握了解降水情况,保证降水效果。(5)、井点降水设备正常工作后,应设置专人24小时不间隔值班,以防出现异常应及时修复。(6)、在临近本工程的建筑物上设置沉降观测点;开始降水时,应缓慢进行,防止降水速度过快,影响原主厂房地基发生不均匀沉降;随时观察原主厂房沉降情况,控制降水速4度。(7)、因基坑范围比较及渗透系数大,宜在基坑中部设置临时井点系统进行辅助降水,井点环不能封闭时,在机械挖土有开行路线入口部位向基坑外侧延长20m作为保护段,以确保降水效果。八、危险点分析1、电源线老化漏电伤人。预防措施:根据水泵电机电流量配置相应电源线,做到一闸一机,漏电保护器动作灵活,交接班时对漏电保护器进行试动作,防止因长时间运行而失灵。2、塌方预防措施:土方施工按要求坡度放坡,设置专人巡视边坡的稳定性,防止土方坍塌事故发生。3、机械伤害预防措施:由于同挖土工程交叉施工,严禁在机械挖土范围内进行人工降水施工,防止机械伤害。4、高处坠落预防措施:在基坑四周设置红白相间警示栏杆,栏杆距基坑不小于1m。防止车辆、人员坠入坑内。十、安全生产及文明施工措施1、进入施工现场的作业人员,必须正确佩戴安全帽及穿戴好劳动防护用品。2、如有交叉作业应设专人监护或有防护措施,否则严禁施工,以免发生物体打击及碰撞事故。3、如在夜间施工安全照明必须充足。4、文明施工责任区划分明确,无死角,责任落实,并设有明显标记,便于检查、监督。5、施工用机械、设备完好、清洁,安全操作规程齐全,操作人员持证上岗,并熟悉机械性能和工作条件。6、施工现场在施工过程中出现的各种坑、沟、孔洞,施工单位应根据实际情况,设置标准的与地平行的安全沟道盖板或可靠的围栏、档脚板或警告标志。7、拉电源时,严禁将电线直接勾挂在闸刀上或直接插入插座内使用,必须用插头连接。8、施工单位应经常组织施工人员进行安全文明施工学习,使每位施工人员掌握安全文明5施工知识,不断地提高安全文明施工意识,做到安全生产文明施工。9、由于井点降水处于湿工作状态下,电源安全装置须达到三级保护要求。十一、环保措施1、井点施工产生的泥浆、弃土应及时清运,运输时必须覆盖,避免产生扬尘和遗撒。2、排出的地下水应经过沉淀处理后方可排入专用管道。天鹅湖小镇189#楼花园洋房降6水井施工方案编制:审核:审批:日期:宁夏大方建筑工程有限公司
本文标题:9井点降水方案
链接地址:https://www.777doc.com/doc-3385875 .html