您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 给排水/暖通与智能化 > 民用建筑给排水施工方案..
给排水、采暖工程施工方案目录第一章、编制依据··················································2第二章、工程概况··················································2第三章、施工准备与施工部署········································5第一节、项目管理策划·······································6第二节、施工准备··········································7第四章、主要施工方法及技术措施····································10第一节、主要施工方法······································10第二节、成品保护措施······································22第三节、质量通病预防······································24第四节、冬雨期施工措施····································24第五章、质量保证措施··············································26第一节、总则··············································26第二节、文件资料和质量记录管理····························27第三节、过程控制··········································27第六章、安全生产措施及规定········································28第一节、安全方针、目标····································28第二节、安全管理··········································29第七章、消防保卫措施··············································31第八章、文明及环境保护措施········································32第一章、编制依据1、嘉定区菊园新区刘家河以西、胜竹路以北地块住宅项目给水工程施工图2、现行国家施工及验收规范和质量检验评定标准《建筑给排水及采暖工程施工质量验收规范》GB50242-2002《建筑安装工程质量检验评定统一标准》GB50300-2001给排水、采暖工程施工方案2《建筑给水聚丙烯管道工程技术规范》GB/T50349-2005《建筑给排水设计规范》GB50015—2003《室外给水设计规范》GB50013--2006《建筑节能工程施工质量验收规范》GB50411-20073、安全标准OHSMS18001《国家经贸委职业安全卫生管理体系试行标准:1999》和公司职业安全卫生管理手册、程序文件施工现场临时用电安全技术规程JGJ46-2005建设工程施工现场供用电安全规范GB50194-93第二章、工程概况1、总体概况本项目位于住宅楼在地下室与车库相互贯通2工程概况表:工程名称建设单位设计单位监理单位施工单位计划开竣工日期3、系统概况列表如下:名称系统简介给排水、采暖工程施工方案3生活给水系统1根据业主提供资料,本基地室外市政给水管网压力不低于﹒0﹒16MPa。从基地西侧永新路市政给水管网接入DN150给水管一根供西区地块室内外生活用水;给水引入管上设水表计量32#地下车库、1~20#楼住宅1~2层、除21#楼外的商业及配套房1~2层用水由市政压力直接供给,1~16#中高层住宅2层以上采用“地下生活水箱—恒压变频供水设备供水至用水点”的加压方式供水。17~20#楼高层住宅2层以上采用“地下生活水箱—生活水箱直供,其中1区(2~8层)、2区(9~15层)由水箱出水经减压阀减压后供水,3区”(16~23层)由水箱直供,4区(24~26层)由屋顶水箱内小型变频加压供水设备供水。21#商业楼1层由市政压力直接供给,2~3层采用“地下生活水箱—恒压变频供水设备供水至用水点”的加压供水方式。在加压供水各用水点处供水压力大于0﹒20MPa处采用支管减压措施。2室内干管采用钢塑复合管(冷水用),管径≤DN80丝扣连接,管径>DN80沟槽式机械配件连接或法兰连接。给水支管采用冷水用无规共聚聚丙烯PP-R管S5级热熔连接。排水系统1住宅室内废污水分流,卫生间排水设专用通气管,厨房单独设置排水管,并设伸顶通气,商业室内废污水合流,公共卫生间排水管增设环形通气管。2屋面雨水单独排放,均为重力外排水系统排放。3室内重力流污水管道,立管及出户管采用静音HDPE排水管及管件,承插粘接。4空调排水、雨水排水管道采用防紫外线型硬聚氯乙烯排水管,承插粘接。给排水、采暖工程施工方案4压力排水系统1压力排水系统为地下室排水,地下车库地面排水经沉沙隔油池处理后由潜污泵提升至室外污水管道。2潜水泵出口管段管道采用热镀锌钢管及配件,管径≤DN80时丝扣连接,管径>DN80时沟槽式机械配件连接或法兰连接。第三章、施工准备与施工部署项目管理策划一、工程管理目标1)质量目标:合格。2)工期目标:开工日期:,总工期395日历天。二、组织机构本工程选派经验丰富、具有复合知识结构的管理人员组成项目经理部。严格履行专业职责,密切配合土建,实现统一计划、统一现场管理、统一施工管理。项目经理部组织机构图如下:暖通责任工程师暖通质量检查员电气责任工程师安装经理电气质量检查员给排水、采暖工程施工方案三、施工协调管理1)加强与设计单位的联系,及时了解设计意图及工程要求。2)施工过程中出现的问题,及时向业主、监理汇报,并同设计单位联系,咨询意见,办理设计变更。3)严格按照图纸施工,未经设计同意不得随意变更设计。4)在施工全过程中,严格按照经业主及监理单位批准的“施工组织设计”进行质量管理。在施工班组“自检”和责任工程师、质检员联合检查的基础上,接受监理的检查和验收,并依照监理通知,按工艺标准予以整改。第二节、施工准备一、施工准备工作流程二、组织准备针对该工程施工要求高,工期相对短的情况下,必须建立一个严密的现场管理体系,实行任务到组、质量到人,严格要求,精心施工。对施工人员进行思想教育和组织建设,加强学习,建全岗位责任制。把技术交底、质量标准、操作工艺、安全消防交底贯彻贯彻到施工班组,要求每一个施工人员牢固树立质量第一的思想,从组织上保证质量及进度。三、技术准备进场前,责任工程师及相关技术人员应认真熟悉图纸及有关技术资料,将管道施工图与结构图、建筑图及专业施工图进行核对,熟悉流程,熟练掌握施工及验收规范标准,熟悉现场环境及土建进度安排、施工管理等情况,拟定与总进度计划相协调的专业施工进度计划。工人进场后,结合本专业和工地实际情况对施工作业人员进行质量教育、安全教育,做好技术交底,明确器具、设备安装的做法及标准,明确各种管道的安装尺寸、坡度、支吊架形式。四、机具准备根据总进度计划及专业进度计划,组织机具进场。所有机具安放在指定的加工场地。主要机具使用计划表如下:核定设备、材料成本编制设备、材料、加工件计划技术交底熟悉图纸图纸会审编制施工技术方案给排水、采暖工程施工方案6序号机具名称规格型号单位数量进场时间1电焊机台22010.82砂轮切割机Φ400台22010.83台钻EQ3025台12011.34电锤ZIC1—16把52011.35气焊工具套22010.86试压泵套22011.47压力案子套32011.48游标卡尺个22010.89水平尺个62010.810压力表个62011.411套丝机台22010.812热熔机台202011.413钢卷尺0—5000mm把502010·8五、物资准备1)开工前完成各项施工用料的调查落实,经过试验合格后签订供货协议,分期分批组织进场。为使设备能够按期抵达现场而不影响安装进度,列出设备、材料的详细进场时间。依据此时间结合各设备的生产供货周期,提前确定各类设备的供货厂商及供货合同,保证设备按时进场。2)根据主要设备、材料需用量计划,及时组织材料进场,保证使用。四、施工进度进度计划1)计划控制目标详见施工进度计划表;2)保证工期措施我公司将根据土建施工网络计划,对工期进行分解,制定阶段目标,制定月、旬、周、日工作计划。以实现对业主的工期的承诺。(1)技术保证措施a.组织技术质量人员学习技术规范、熟悉施工图纸。b.提前做好各分项工程的施工方案与材料试验,及时申报。(2)劳动力保证措施根据总体施工控制进度计划,做出劳动力使用计划,加强劳动力调度,选派有同类工程施工经验的队伍进场施工,从数量、素质予以保证。(3)材料保证措施a.保证料源充足,开工前做出备料计划,提前考察各种材料的货源、储量、运距等,详细制定出进料计划,保证各种物资的供应。b.把材料质量关。在经过考察的基础上,采购合格的原料与半成品,防止因不合格材料影响工期。c.每月做出具体的材料使用计划与进场计划,若有遗漏,及时做出追补计划。(4)加强质量管理工作每个分项工程及部位施工前,责任工程师须以书面形式对施工队伍进行交底,包括使用材料、安装方法、技术要求、质量标准以及美观要求、成品保护,工期要求等,根据公司质量保证体系,对施工班组进行检验与监督。(5)加强施工部署和各专业间的相互配合。给排水、采暖工程施工方案7五、劳动力计划根据本工程特点,项目部将根据施工进度计划优化人力、机械、材料、资金、技术等生产要素,并根据施工阶段性要求,满足项目施工的动态管理,确保工序作业紧密连接,杜绝一切可能发生的隐患,充分调动所有人员的积极性,确保工期、质量目标的实现。工种安装开始阶段安装施工高峰调试阶段保温工252管工103018焊工3520510152025303540安装开始阶段安装高峰阶段调试阶段保温工管工焊工第四章、主要施工方法及技术措施第一节、主要施工方法一、系统基本工艺流程二、管材的选用及连接方式1)生活给水干管采用钢塑复合管,管径≤DN80时丝扣连接,管径>DN80时沟槽式机械配件连接或法兰连接,给水支管采用PP-R管,热熔连接。2)室内排水管及出墙埋地排水管采用DHPE管,粘接连接。3)室外排水管采用防紫外线UPVC管,粘接连接4)地下室压力排水管采用热镀锌钢管,管径≤DN80时丝扣连接,管径>DN80时沟槽式机械配件连接或法兰连接。5)三、孔洞预留、套管安装(一)预留范围:配合结构施工,在砼楼板、梁、墙上预留孔、洞、预埋件安装准备预留孔洞、埋件套管安装管道预制加工支、吊架制作支、吊架安装管道安装设备及附件安装孔洞处理管道试水管道刷漆、防腐、保温系统调试竣工验收通水试验给排水、采暖工程施工方案8及套管。(二)预留工作准备1、施工前仔细阅读理解机电施工图纸,并结合结构图纸制作综合机电设备留孔图,在施工前一个月提交监理、业主审批作为预留预埋施工依据。2、专业工程师按照综合机电设备留孔图,确定所有预埋预留点,并统一编号,并对照机电施工图与土建结构图重新核对预留位置、孔洞尺寸、标高。3、组织预留预埋施工协调会,确定预留孔洞与预埋件的责任划分。制定预留预埋检查与交接的具体措施,并确定责任人。4、相关技术人员核实预埋件规格数量,落实预埋件的预埋方法。(三)预留施工及技术要求1、预留孔洞(1)一般孔洞预留:结构施工过程中,确定专人跟踪配合,待土建施工到预留孔洞部位时,立即按机电设备留孔图中给定的穿管坐标和标高,在模板上作出标记。在土建扎钢筋时,将事先做好的模具中心对准标记进行模具的固定安装,并考虑方便拆除临时模具。当遇有较大的孔洞、模具与多根钢筋相碰时,与土建技术人员协商,采取相应措施后再进行安装固定。(2)孔洞预留:参照图纸及设计要求进行预留。不允许偏差,孔洞的尺寸可适当放大一号。(3)楼板预留洞注意事项1)预留洞
本文标题:民用建筑给排水施工方案..
链接地址:https://www.777doc.com/doc-4189105 .html