您好,欢迎访问三七文档
当前位置:首页 > 机械/制造/汽车 > 综合/其它 > windchill PDM硬件项目安装实施报告
winchillPDM硬件项目安装实施报告1windchillPDM硬件项目安装实施报告2008年3月21日winchillPDM硬件项目安装实施报告2目录第一章安装部署架构及安装规划.............................................................................................31.1.系统设备概述...............................................................................................................31.2.应用系统支撑范围.......................................................................................................31.3.硬件拓扑图...................................................................................................................41.4.DS4700存储划分.........................................................................................................51.5.主机、存储IP规划.....................................................................................................61.6.主机端文件系统划分...................................................................................................61.7.双机模式.......................................................................................................................7第二章PDM系统日常维护方法...........................................................................................82.1启动,停止PDM系统双机........................................................................................82.2DS4700存储快照脚本使用方法...............................................................................122.3TSM备份软件日常维护............................................................................................15winchillPDM硬件项目安装实施报告3第一章安装部署架构及安装规划1.1.系统设备概述产品描述数量生产服务器8路Power5+1.8GCPU,24G内存,2个千兆光纤存储卡,1个千兆网卡(共3个千兆网口),磁带机,DVD-ROM,图形显示卡,2块内置硬盘(73GB,15Krpm),操作系统AIX(无限用户)2开发测试机4路1.65GHzPower5+cpu,12G内存,4*146硬盘,2*1000M以太网口,2*4GB光纤卡,内置磁带机,DVD-ROM,图形显示卡,2块73G15Krpm内置硬盘、4块146G15Krpm内置硬盘,操作系统AIX(无限用户)1IBM存储服务器DS4700磁盘阵列柜DS47002G高速缓存,16块146G硬盘(15Krpm),支持SAN存储结构,快照软件1光纤交换机B16光纤交换机,激活8端口2磁带库LTO3驱动头,1盒清洗带,5盒400G/800G数据带1Tsm备份软件Tsm备份软件安装包,支持网络备份,支持光纤通道LAN_FREE备份,支持数据库备份11.2.应用系统支撑范围1.PDM生产机数据库系统2.PDM生产机windchill应用系统3.PDM开发系统winchillPDM硬件项目安装实施报告41.3.硬件拓扑图P5618C/24Gmem光纤交换机B16光纤交换机B16TS3100磁带库DS4700存储2.3T裸盘容量快照软件网络设备网络设备P52A4C/12GmemPDMDB主机开发机P5618C/24GmemPDMAPP主机HAwinchillPDM硬件项目安装实施报告51.4.DS4700存储划分ServerVGnameSystemTypeNumbersofDisk(146G)SizeRAIDTypeprddbplm3oravg01FS&DB1080GRAID5oravg02FS&DB1080GRAID5oravg03FS&DB1080GRAID5oravg04FS&DB1080GRAID5windchillvg01FS&DB10250GRAID5windchillvg02FS&DB10250GRAID5prddbprddb_ptcvgFS&DB1050GRAID5plm3plm3_ptcvgFS&DB1050GRAID5plm3dev采用内置硬盘FS&DB///备注:1块146G硬盘作为全局热备份盘,留两块146G硬盘备用winchillPDM硬件项目安装实施报告61.5.主机、存储IP规划a)两台P561IP地址规划主机名BootIP/掩码标签StandbyIP/掩码标签ServiceIP/掩码prddb192.168.100.1/16prddb_boot192.168.101.1/16prddb_stby10.5.1.131/16prddbplm3192.168.100.2/16plm3_boot192.168.101.2/16plm3_stby10.5.1.132/16plm3网关IP10.5.1.254b)DS4700存储IP地址规划主机名控制器A控制器B备注DS470010.5.1.133/1610.5.1.139/16主用IPDS4700192.168.129.101/16192.168.129.102/16备用IP网关IP10.5.1.254c)开发机P52AIP地址规划主机名BootIP/掩码标签维护生产机临时增加ipplm3dev10.5.1.114/16plm3dev192.168.100.111/16增加方法:#ifconfigen0192.168.100.111alias1.6.主机端文件系统划分LvType磁盘容量Mountpoint所属于卷主lvoracleJfs210G/oracleoravgwinchillPDM硬件项目安装实施报告7LvType磁盘容量Mountpoint所属于卷主lvoradataJfs2100G/oradataoravglvorainstcdJfs210G/orainstcdoravglvarchiveJfs230G/oracle/product/10.2.0/dbs/archoravglvprddbptcJfs245G/ptcprddb_ptcvglvfilevaultJfs2100G/filevaultwindchillvglvwin9Jfs220G/win9windchillvglvotherJfs2100G/otherwindchillvglvbackupJfs220G/backupwindchillvglvplm3_ptcJfs245G/ptcplm3_ptcvg1.7.双机模式根据上面方案的设计要求,采用cascadingcluster双机方式。通常称互备方式的cluster,一般情况下每台主机运行一个service,如果发生故障时所有的业务都运行在一台主机上面。appclustername:pdmclusterappclusternode1:prddbappclusternode2:plm3Servicename:oraappServicename:windchillappResourcegroup:ora_rgResourcegroup:windchill_rgwinchillPDM硬件项目安装实施报告8第二章PDM系统日常维护方法2.1启动,停止PDM系统双机1.系统正常启动后只会启动两个ip地址,一个是bootip,一个是stbyip,浮动ip地址10.5.1.131只有在双机正常启动后才能挂接。2.可以通过开发机连接192.168.100.1和192.168.100.2的ip地址。方法:在开发机en0网口上增加一个ip,#ifconfigen0192.168.100.111aliaswinchillPDM硬件项目安装实施报告93.在数据库服务器prddb上执行smittyclstart命令启动双机(启动完数据库服务器后,应用服务器plm3也需要执行smittyclstart命令)。4.双机启动后日志放置在/var/hacmp/log/hacmp.out文件中,可以用vi或者tail命令查看。winchillPDM硬件项目安装实施报告105.双机正常启动后,可以自动挂接vg和文件系统,加载浮动ip,启动数据库。双机自动拉起数据库的启停脚本放置在/etc/byd3hacmp目录下。winchillPDM硬件项目安装实施报告116.双机切换测试,在命令行界面执行smittyclstop,选择MoveresourceGroups后回车。执行切换。(等同于主机出现宕机情况下的切换)。双机切换完成后,会在plm3主机上挂接文件系统,加载10.5.1.131的ip,启动oracle服务。7.当prddb主机恢复正常时,用smittyclstart命令启动双机,会把oracle服务拉回prddb主机。8.需要停止双机系统时,先停止plm3主机,再停prddb主机。执行smittyclstop命令,选winchillPDM硬件项目安装实施报告12择BringRresourceGroupOffline即可。2.2DS4700存储快照脚本使用方法1.快照脚本存放位置:存放于prddb和plm3主机的/etc/flashcopyfiles文件下,主脚本为fc-all.080321文件,其余为调用脚本。2.刷快照过程,整个过程大概30秒左右:a)首先先umount和删除上次产生的快照文件系统和vgb)将数据库置于backup状态,此状态用户只能对数据库只能进行读操作,不能写c)DS4700存储刷快照d)将数据库置于正常online状态e)挂接快照产生的文件系统和vg3.快照脚本可以在crontab–e文件中每天自动调度执行4.刷快照部分截图a)刷快照前在plm3主机上已经挂接上次执行快照脚本后挂接的vg和文件系统。vg名称是testvg1,文件系统以/fs为挂接目录。b)执行/etc/flashcopyfiles/fc-all.080321脚本。执行过程中没有报错,一般表示已经顺利完成,详细信息可以查看日志。winchillPDM硬件项目安装实施报告13c)日志目录存放在/etc/flashcopyfiles/flcp.log下。winchillPDM硬件项目安装实施报告14d)快照刷完成后可以在plm3主机上看到以/fs开头的文件系统。e)以下在crontab中自动调用快照脚本时间是每天中午13:00,时间可以更改winchillPDM硬件项目安装实施报告152.3TS
本文标题:windchill PDM硬件项目安装实施报告
链接地址:https://www.777doc.com/doc-4577361 .html