当前位置:首页 > 建筑/环境 > 工程监理 > 高压线路杆塔受力计算表3.3
一、35电压35kV12345-70/10-70/40-95/20-95/55-120/7铝68.0569.7395.1496.51118.89钢11.3440.6718.8256.306.61合计79.39110.40113.96152.81125.50铝钢比6.001.715.061.7117.99外径d(mm)11.4013.6013.8716.0014.50计算拉断力P(N)2339058300372007811027570计算重量G1(kg/m)0.27520.51130.40890.70770.3790弹性模量E(N/mm2)790001050007600010500066000线膨胀系数α(1/℃)1.91E-051.53E-051.85E-051.53E-052.13E-05破坏应力σp(N/mm2)最大使用应力[σm]安全系数K[σpj]σp×%项目温度℃风速m/s冰厚mm最高气温40--3最高最低覆冰大风安装最低气温-10---5最大风速-525-最大覆冰-5105-5安装情况-510--20-10事故情况-5---1010-5大气过电压1510--20-10操作过电压1515--40-15年平均气温15--冰比重年雷电日40-10-5-5-10自重比载g1=冰重比载g2=垂直总比载g3=导线g4(M)=0.85g4(15)=1.00g4(10)=1.00覆冰时风压比载g5=1.00g6(M)=g6(15)=g6(10)=覆冰时综合比载g7=294.5白色文字图例9.81*0.9πb(b+d)/A×10-39.81αCdv2/16/A×10-3(g32+g52)0.5地线导线0.00001151178.1-49.4649.46-274.031.679582710.4241814239.81αCdv2/16/A×10-3275.967.7121.60109.610.0000196756200.92222.50.00527897≥40比载种类 Ⅸ Ⅷ年平均运行应力无冰时风压比载9.81αCdv2/16/A×10-30.028045无冰时综合比载(g12+g4(10)2)0.50.033205260.03486834(g12+g4(15)2)0.50.04314183(g12+g4(M)2)0.50.089329280.110140680.085156060.12654955 Ⅰ Ⅴ0.08409705比载(N/m.mm2)导线地线-5392.713.025%010-5 Ⅶ2、设计气象条件组合表68.5 Ⅱ Ⅲ25%kV输电线路基本参数比载计算公式0.9陈家冲-下岸溪9.81αC(d+2b)v2/16/A×10-3典型气象区244.29730001、导、地线的机械物理特性表机械物理特性0.013368009.81×G1/A计算截面A(mm2)1.201.10表示公式\数据\过程\备查。黄色填充表示提请特别注意。0.123352950.030123210.013388090.07112424气温风载体形系数C=表示窗口或者提示。0.039255900.008425030.02826375编者的话土色填充风速不均匀系数α=现在是备注0.046913660.011877690.046150950.03278295 Ⅳ Ⅵ自定义g1+g23、导、地线比载计算表红色文字-10-20表示需要人为调整。呵呵!导线、地线规格不全,如果需要,参数可在后面自定义栏改,但不是很方便,将就一下吧?!^_^ →40-5-10控制应力气象条件控制应力σk气温最低气温109.61g1=-10年平均气温68.51g1=15最大风速109.61g6(M)=-5最大比载109.61g7=-5LljAB=189.5LljBC=0.0LljCD=-1.0LljAC=158.4LljBD=-1.0LljAD=-1.0导线受控制h=6.0mLk=833.0←导线受控制控制应力σD=51.69←σB=145.86←294.54否!392.71气象条件控制应力σk气温最低气温392.71g1=-10年平均气温294.54g1=15最大风速392.71g6(M)=-5最大比载392.71g7=-5A最低气温392.71g1=-10B最大风速392.71g6(M)=-5C年平均气温294.54g1=15D最大比载392.71g7=-5LljAB=205.1LljBC=-1.0LljCD=578.5*LljAC=-1.0LljBD=0.0LljAD=154.3地线受控制109.61比载Ⅱ0.046913660.032782950.04314183Ⅰ0.03278295临界档距Llj=[(24α(ti-tj)+24(σki-σkj)/E)/((gi/σki)^2-(gj/σkj)^2)]^0.50.00039359年平均气温最大比载g/σk比值从小到大重新排是否按σB计算地线应力?可能的控制气象条件计算临界档距,确定控制条件最大使用应力[σm]=4、导线临界档距计算0.0003935968.510.00029909计算临界档距,确定控制条件临界档距Llj=[(24α(ti-tj)+24(σki-σkj)/E)/((gi/σki)^2-(gj/σkj)^2)]^0.5ⅠⅡⅢ1,导地线悬挂点高差2,控制档距3,导线在大气过电压无风时的应力4,地线在大气过电压无风时的应力地线最大使用应力[σm]=0.126549550.084097050.110140680.000280460.110140680.00028046为便于计算,将上表中数据按g/σk比值从小到大,重新排列:⑷0.00032224小↓↓大g/σk比值σn3-Bσn2-A=0,A=gn2Lk2E/24,B=σm-gm2Lk2E/(24σm2)-αE(tn-tm)从导线气象条件控制范围看Lk档距下0.084097050.000285520.000214140.084097050.00028552可能的控制气象条件比载5,地线年平均运行应力[σpj]=0.126549550.000322240.084097050.00021414为了满足防雷要求,在大气过电压、无风时,档距中央导、地线间最小距离s≥0.012L+1m,此时应该使σB≥gB/(gD/σD-2.88*10-4/(h-1))5、地线临界档距计算由地线在大气过电压无风时的参数,计算地线在其他可能的控制气象条件时的应力g/σk比值0.00047854年平均运行应力[σpj]=0.000299090.000428000.000428000.00047854⑷Ⅲ年平均气温6789101112131415LGJ-70/10161718-120/20-120/25-120/70-150/8-150/20-150/25-150/35-185/25-185/30-185/45LGJ-70/40-210/10-210/25-210/35115.67122.48122.15144.76145.68148.88147.26187.04181.34184.73LGJ-95/20204.14209.02211.7318.8224.2571.258.0418.8224.2534.3624.4529.5943.10LGJ-95/5511.3427.1034.36134.49146.73193.40152.80164.50173.11181.62211.49210.93227.83LGJ-120/7215.48236.12246.096.155.051.7118.007.746.134.297.656.134.29LGJ-120/2018.007.716.1615.0715.7418.0016.0016.6717.1017.5018.9018.8819.60LGJ-120/2519.0019.9820.3841000478809837032860466305411065020594206432080190LGJ-120/704514065990742500.46680.52660.89560.46140.54940.60100.67620.70610.73260.8482LGJ-150/80.65070.78910.8539760007600010500066000730007600080000730007600080000LGJ-150/206600073000760001.89E-051.85E-051.53E-052.13E-051.96E-051.89E-051.78E-051.96E-051.89E-051.78E-05LGJ-150/252.12E-051.96E-051.89E-05LGJ-150/35GJ-2520LGJ-185/25GJ-35LGJ-185/30GJ-503LGJ-185/45自定义LGJ-210/10LGJ-210/25LGJ-210/35雷电操作年均最大覆冰安装雷电操作LGJ-210/5035150LGJ-240/3030LGJ-240/40LGJ-240/55自定义3025301520152510101015101-67-1213-1819-23244.2931.67地线275.967.7121.60756200.9222730001.96E-0510515151.201.20表示公式\数据\过程\备查。表示提请特别注意。2020年3月29日气温风载体形系数C=2时38分风速表示窗口或者提示。备注覆冰厚度1530251010201015表示需要人为调整。-510呵呵!导线、地线规格不全,如果需要,参数可在后面自定义栏改,但不是很方便,将就一下吧?!^_^ →10151510代码A最低气温109.61g1=-10B最大风速109.61g6(M)=-5C最大比载109.61g7=-5D年平均气温68.51g1=15----Llj---(m)----年平均气温年平均气温年平均气温控制条件t=t=g1=g1=A=A=B=B=公式公式σ=σD=t=gi=A=B=公式σ=--C控制D控制+Llj--578.47(m)--年平均气温最大比载年平均气温578.5m最大比载临界档距Ldlj=145.860.0840970已知-1556.16最大比载-1545.7337096472.04-5-10小于[σpj],OK验算:年平均气温时的应力其值不得超过地线允许值→0.000.00-可变单元格→147.990.000.12654955217.62不需要按σB计算地线应力,故不需要计算1→-150-50.043141832268284.90.03278295最低气温时导线的参数求大气过电压无风时导线参数-797.13由地线在大气过电压无风时的参数,计算地线在其他可能的控制气象条件时的应力为便于计算,将上表中数据按g/σk比值从小到大,重新排列:0.032782950.043141830.000393590.00047854--[单变量求解]目标值=“0”150.04691366小↓↓大0.000299090.00042800临界档距Ldlj=0.03278295年平均气温-1597.8984002525.1651.6937096472.04待求年平均气温68.510.0840970515-气象条件控制范围图[单变量求解]目标值=“0”目标单元格→可变单元格→大气过电压无风时145.86-0.08409705目标单元格→气象条件控制范围图19202122123-210/50-240/30-240/40-240/55-240/55GJ-25GJ-35GJ-50GJ-50209.24244.29238.85241.27241.27----48.8231.6738.9056.3056.3026.6037.1549.4650.00258.06275.96277.75297.57297.5726.6037.1549.4650.004.2
本文标题:高压线路杆塔受力计算表3.3
链接地址:https://www.777doc.com/doc-4615885 .html