您好,欢迎访问三七文档
当前位置:首页 > 行业资料 > 交通运输 > AEG UPS介绍演示(工业)
Powersolutionsforaworldonthemove工业UPS介绍2005-7-152CompuMaster300/600/1200[VA]输出:单相离线技术PROTECTS./PROTECTS.19700/1000/1500/2000/3000[VA]输出:单相在线技术SVSPROTECT1.11/314,5/6/7,5/10[kVA]输出:单相在线技术SVSPROTECT1.3310/15/20[kVA]输出:三相在线技术用于IT业的UPSSVSPROTECT3.3310/20/30/40/60/80/100/120[kVA]输出:三相在线技术SVSPROTECT4.33160/220/300/400/500/600/800/1000[kVA]输出:三相在线技术多用UPS工业用UPSUPS系列产品SVSPROTECT3.3110/20/30/40/60/80/100/120[kVA]输出:单相在线技术SVSPROTECT5.3110/20/30/40/60/80/100/120[kVA]输出:单相在线技术SVSPROTECT5.33输出:三相在线技术10/20/30/40/60[kVA]输出:单相在线技术ProfitecS+Transokraft(Inv3)30/50/80/120/170[kVA]输出:三相ProfitecS+PROTECT5.Inv325/40/60/80/100/120[kVA]输出:三相ProfitecS+PROTECT5.Inv125/40/60/80/100/120[kVA]3用于IT业的UPSUPS系列产品5UPSforIndustry市场范围6工业市场产品UPSforIndustrySVSPROTECT5.3110/20/30/40/60/80/100/120[kVA]Output:1-phaseOn-Line-TechnologySVSPROTECT5.33Output:3-phaseOn-Line-TechnologyOutput:1-phaseOn-Line-TechnologyProfitecS+Transokraft(Inv3)30/50/80/120/170[kVA]Output:3-phasePROTECT5.Inv325/40/60/80/100/120[kVA]Output:3-phasePROTECT5.Inv125/40/60/80/100/120[kVA]10/20/30/40/60/80/100/120[kVA]7ElectricalfunctionThefollowingslidesshowthebasicschematicsofthesystems.Thisismadetoeasilyexplainallitemsofasystemwiththeadvantages.8ElectricalfunctionProtect5.31DisplayandoperationboardRectifiercontrolsystemInvertercontrolsystemwithDSPStaticswitchcontrolsystemRectifierInverterStaticswitchManualbypassLOADMAINSBYPASS9ElectricalfunctionProtect5.33RectifiercontrolsystemInvertercontrolsystemwithDSPStaticswitchcontrolsystemDisplayandoperationboardLOADBYPASSMAINSRectifierInverterStaticswitchManualbypass10ElectricalfunctionProtect5.3312pulseinputRectifiercontrolsystemInvertercontrolsystemwithDSPStaticswitchcontrolsystemDisplayandoperationboardLOADBYPASSMAINSInverterStaticswitchManualbypassRectifier11~==~~==~NormalMainsLoadSafeloadbusLoadLoadLoadAlternateMainsBattery2Battery1ManualBypassUPS1UPS2AllInclusive:-integratedSBSsolution-nocentralSBSmeansfullredundancy-integrated12-pulsesolutionasstandard-veryhighefficiencyresultsintolowoperationcostSBS1SBS22UPSinParalleloperation122UPSinParalleloperation13ParallelUPSwithsinglebattery14InputTHDThenextslidesgivetheinputTotalHarmonicDistortion6pulserectifier(整流)6pulse+filterrectifier(滤波)12pulserectifier(整流)156-pulse40KVAUPS六脉冲波型图Mainscurrentwithnominalload:UPS40kVAwith6-pulsRectifier166-脉冲滤波器40KVAUPS加滤波器波型图Mainscurrentwithnominalload:UPS40kVAwithFilter1712脉冲12脉冲波型图Mainscurrentwithnominalload:UPS120kVAwith12-pulseRectifier18THD6pulse/6pulse+filter/12pulse谐波表Mainspertubation:MainsharmoniccurrentsMainsharmonicdistortion40kVAwith6-pulsrectifier40kVAwithsinusoidalpowerconsumption120kVAwithsinusoidalpowerconsumptionSVSProtect3.19PrinciplelayoutofaUPSsystemStaticbypassswitchSBSRectifierInverterIsolationtransformerManualbypassswitchBatteryLoadrectifierinverter20WhataretheefficienciesrectifierLossesintheinputtransformerLossesintheinputchokeslossesintherectifierbridgeLossesintheDCchokes.inverterSwitchinglossesintheinverter(switchingandconducted)FilterlossesforsinewaveoutputvoltageTransformerlossesintheoutputandVentilation(fans)21负载效率Theefficiencyisthehighestatpartialload50%OverallEfficiencyACtoACEfficiency1,000,950,900,850,800,750,700102030405060708090100Load(%)22InputvoltageandinputPowerfactorWhatisthepowerfactorTherelationbetweenInputapparentpowerandinputpower(kVA/kWatt)WhydowehaveapowerfactorTheDCvoltageneedstoberegulatedtohaveacorrectchargingvoltageforthebattery.Thisneedstobedoneat:Lowmainsvoltage,Noloadandfullload,highmainsvoltage,highandlowmainsfrequency.WeuseThyristorchargerwithphasecontrol,dependingontheDCvoltagelevel,thephaseangelofthethyristorcontrolwillbechanged.Thephaseangelisoptimisedfor100%loadandnominalinputvoltagetoreachavalueof0.8.WhatisthedifferencebetweenPowerfactorandCosThepowerfactorincludesallharmonicsTheCosisthedisplacementofonlythegroundfrequency.(e.g.50or60Hz)23WhatisphasecontrolNormalmainsvoltageHighmainsvoltageLowmainsvoltagePhaseangelBigNormalSmallTimeVoltageAmplitude24InputPowerfactorinrelationtomainsvoltage0,70,720,740,760,780,80,820,840,86I/Inenn255075100380VPF400VPF415VPFLoadcurrentPowerFactor25InputpowerfactorwithinputfilterPowerfaktorataUPS40kVAwithFilterMainsinputvoltage380V400V415V0,750,80,850,90,9510102030405060708090100380V400V415V26VFITECHNOLOGYFIRSTCLASSUPSbyAEGSVSInverterOverloadCapability-Advantagebyanintelligentthermalmanagementbetweenfixedpoints:I2xt125%-10min150%-1min100%-continuous270%/100ms-5s/1-phase180%/100ms-5s/3-phases180%150%125%100%1min10min015minOverloadcapabilityAEGUPSsystems27OutputcosphiProtect5maximunofoutputcurrentcomparedtothenominalcurrentdepndingofthePowerfactoroftheloadcurrent00,20,40,60,811,200,10,20,30,40,50,60,70,80,910,90,80,70,60,50,40,30,20,10PowerfactorI_load/I_nomcapind28VFITECHNOLOGYtriple„FIRSTCLASS“UPSbyAEGSVSINVoperationMAINSoperation(INVERTERFAULT)IINVIBypass.ULoadINVoperationResponseonINVERTERFAULT-TransfertoBypass:(worstcase)Classification1==VFISS11129VFITECHNOLOGYtriple„FIRSTCLASS“UPSbyAEGSVSOutputDeviationbylinearLoadStepscontrolbya
本文标题:AEG UPS介绍演示(工业)
链接地址:https://www.777doc.com/doc-5400133 .html