您好,欢迎访问三七文档
AirfieldCablesIssue10/20033PiktogrammeBrClFlTemperaturePermissibleambienttemperatureWeatherResistancetosevereweatherconditionsImpactsCablemechanicalresistancetoimpactsChemicalattacksResistancetochemicalsFlame-FireCablefireperformancesCorrosivityToxicityFlexibilityBendingRadiusR=nxcablediameterHalogenfreeWater-tightnessElectroMagneticInterferenceRAirfieldLightnigCablesVoltageTemperaturePage1.AirfieldLightningCablesIntroduction72.CablesPrimaryCircuitCablesFLYCY1/2kV-2.5/5kV-3/6kV90°C6FL2XCY6/10kV90°C8FL2XCYRY6/10kV90°C10RHDt6/10kV90°C12RHV6/10kV90°C14FAAL-824C5kV90°C16AdaptedtoFAAL-824C5kV90°C18SecondaryCircuitCablesH07RN-F450/750V85°C20FLGG500V90°C224AirportCables400HzCablesVoltageTemperaturePage3.400HzCablesIntroduction244.CablesRHEYGROUND400Hzunscreened0.6/1kV70°C26RHEYGROUND400Hzscreened0.6/1kV70°C28RHEYCORD400Hz0.6/1kV90°C32RHEYPUR400Hz0.6/1kV90°C34Withtheissueofthiscatalogueallformercatalogues(alsowithoutdatefoissue)areinvalid.5RegardingtheAirfieldLightingcables,NexansproposesacompleterangeofPrimary,SecondaryandRemotecontrolcables.ThePrimaryisusedbetweenConstantCurrentRegulators(CCRs)andtransformers,theSecondarybetweenAirfieldLightingCableIntroductiontransformersandlights,andtheRemotecontrolbetweenControlTowerandConstantCurrentRegulators(CCRs).ThesecableshavebeeninstalledformanyyearsinmanyAirportsandAirBasesallovertheworld.GermanyNordholz,Fuhlendorf,Kyritz,Cuxhaven,Braunschweig,Tuttlingen,HannoverRussiaMoscow,Ufa,VnukovoCzechRepublic1AirportAzerbaijanBakuNamibiaWindhoekSouthAfrica1AirportSpainGerona,BarcelonaMainReferencesInstallationPrincipleforthePowerPartofAirfieldLightningSystemsStandardPowerCablesSecondaryCircuitCablesPrimaryCircuitCables(seriellcircuit)ConstantCurrentRegulatorsApplicationsAirfieldLighting(high-voltageelectricprimarycircuits,connectedinseries)Design1.ConductorSolidbarecopper(RE)2.InsulationPVC(polyvinylchloride)3.Tape(optional)4.ScreenConcentriclayerofbarecopperwires,counterhelixofacoppertape5.OuterSheathPVC(polyvinylchloride)Colour:black(1x6RE/2.5-1/2kV)red(1x6RE/4-2.5/5kV)red(1x6RE/4-3/6kV)MarkingNEXANSVDE-Reg.-Nr.7664FLYCY1x6RE/2.5-1/2kVNEXANSFLYCY1x6RE/4-2.5/5kVNEXANSVDE-Reg.-Nr.7664FLYCY1x6RE/4-3/6kV6StandardsENV50213(EuropeanPre-Standard)IEC50602-2(Project)FLYCYPrimarycircuitcable1x6RE/2.5-1/2kV1x6RE/4-2.5/5kV1x6RE/4-3/6kVMaxcoretemperature:90°CFlameretardantRigidGoodGoodGood-40/+90°CGoodGoodFLYCY1x6RE/2.3-1/2kV71x61.52.51.410.017011kV/5minCrosssectionInsulationCrosssectionOutersheathOuterWeightTestvoltagethicknessofscreenthicknessdiameternominalnominalnominal(mm2)(mm)(mm2)(mm)(mm)(kg/km)min.Bendingradius:150mmFLYCY1x6RE/4-2.5/5kV1x63.041.413.025011kV/5minCrosssectionInsulationCrosssectionOutersheathOuterWeightTestvoltagethicknessofscreenthicknessdiameternominalnominalnominal(mm2)(mm)(mm2)(mm)(mm)(kg/km)min.Bendingradius:195mmFLYCY1x6RE/4-3/6kV1x63.041.413.025011kV/5minCrosssectionInsulationCrosssectionOutersheathOuterWeightTestvoltagethicknessofscreenthicknessdiameternominalnominalnominal(mm2)(mm)(mm2)(mm)(mm)(kg/km)min.Bendingradius:195mmOthervoltages,conductordesign(class2andclass5)andcolorsofsheathonrequest.RRRApplicationsAirfieldLighting(high-voltageelectricprimarycircuits,connectedinseries)Design1.ConductorStrandedbarecopper(RM),Class2(7wires)2.InsulationExtrudedtripledielectricofinternalsemi-conductornaturalcoloredcross-linkedPolyethylenXLPEinsulationandexternalsemi-conductor(strippable)3.ScreenConcentriclayerofbarecopperwires,counterhelixofacoppertape5.OuterSheathPVC(polyvinylchloride)Colour:redMarkingNEXANSVDE-Reg.-Nr.7676FL2XCY1x6RM/66/10kV8StandardsENV50213(EuropeanPre-Standard)IEC60502-2(Project)FL2XCY1x6RM/6Primarycircuitcable6/10kVMaxcoretemperature:90°CFlameretardantRigidOilresistantGoodGood-40/+90°CGoodGoodFL2XCY1x6RM/691x60.33.50.46≤5pC1.415.642015kV/(10kV)5minCrossThicknessInsulationThicknessCrossPartialOuterOuterWeightTestsectionofinternalthicknessofexternalsectiondischargesheathdiametervoltagesemi-nominalsemi-ofscreentestthicknessnominalconductor*conductor*nominal(mm2)(mm)(mm)(mm)(mm2)(mm)(mm)(kg/km)min.Bendingradius:235mmOthervoltages,conductordesign(class1andclass5)andcolorsofsheathonrequest.*ReferencevalueRApplicationsAirfieldLightingprimarycircuit(connectedinseries)inzoneswiththeriskofmechanicaldemaging.Design1.ConductorBarecopper,Class22.InsulationExtrudedtripledielectricofinternalsemi-conductornaturalcoloredcross-linkedPolyethylenXLPEinsulationandexternalsemi-conductor(strippable)3.ScreenConcentriclayerofbarecopperwires,counterhelixofacoppertape4.SheathPVCColour:red5.ArmouringSteelwires,layedinahelix.6.OuterSheathPVCColour:redMarkingNEXANSFL2XCYRY1x6RM/66/10kV10Standardsadaptedto:ENV50213(EuropeanPre-Standard)IEC60502-2(Project)FL2XCYRY1x6RM/66/10kVMaxcoretemperature:90°CFlameretardantRigidOilresistantGoodGood-40/+90°CVerygoodGoodFL2XCYRY1x6RM/61160.33.50.46≤5pC0.91.420.571015kV/(10kV)5minCrossThicknessInsulationThicknessCrossPartialDiameterOuterOuterWeightTestsectionofinternalthicknessofexternalsectiondischargeofsheathdiametervoltagesemi-semi-oftest
本文标题:机场电缆
链接地址:https://www.777doc.com/doc-60085 .html