ICS27.100F24备案号:40038-2013中华人民共和国电力行业标准DL/T1212—2013火力发电厂现场总线设备安装技术导则Guidefortechnicaloffieldbusdeviceinstallationinfossilfuelpowerplants2013-03-07发布2013-08-01实施国家能源局发布DL/T1212—2013I目次前言··········································Ⅱ1范围·········································12规范性引用文件····································13术语、定义和缩略语··································14现场总线设备安装···································24.1一般要求······································24.2现场总线仪表····································24.3现场总线执行设备··································34.4现场总线通信组件及连接件·······························45现场总线电缆/光纤安装································45.1一般要求······································45.2现场总线电缆/光纤的敷设································55.3电缆接头······································65.4接线········································66防护和接地······································66.1防护要求······································66.2接地要求······································77安装验收·······································77.1一般要求······································77.2现场总线设备安装验收·································77.3通信电缆安装验收··································87.4防护和接地验收···································87.5安装后测试·····································8附录A(资料性附录)通信光纤及电缆特性························10附录B(资料性附录)PROFIBUSDP通信速率与传输范围··················12附录C(资料性附录)安装验收记录表··························13附录D(资料性附录)安装后测试记录表·························15DL/T1212—2013II前言本标准按照GB/T1.1—2009《标准化工作导则第1部分标准的结构和编写》的规则起草。本标准由中国电力企业联合会提出。本标准由电力行业热工自动化与信息标准化技术委员会归口并解释。本标准起草单位:西安热工研究院、广东省电力设计研究院、中国神华胜利能源分公司本标准主要起草人:曾卫东、吴国瑛、王春利、崔逸群、周育勇。本标准为首次发布。本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二条一号,100761)。DL/T1212—20131火力发电厂现场总线设备安装技术导则1范围本标准规定了火力发电厂现场总线设备在施工阶段的安装及安装测试过程中的技术要求及验收规范。本标准适用于遵循PROFIBUS、FF现场总线标准的通信网络和现场总线设备的施工及安装,其他类型现场总线设备可参考使用。2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB/T20540测量和控制数字数据通信工业控制系统用现场总线类型3:PROFIBUS规范GB50254电气装置安装工程低压电器施工及验收规范DL/T701—2012火力发电厂热工自动化术语DL/T5182—2004火力发电厂热工自动化就地设备安装、管路及电缆设计技术规定IEC61158工业通信网络—现场总线规范(Industrialcommunicationnetworks-fieldbusspecifications)3术语、定义和缩略语3.1现场总线fieldbus一个数字化的、串行、双向传输、多分支结构的通信网络系统,是用于工厂/车间仪表和控制设备的局域网。IEC61158分别规定了基金会现场总线H1和HSE、ControlNet、DeviceNet、Profibus、P-Net、WorldFIP、Interbus、EtherCAT、Sercos、VNET/IP、CC-Link、EPA等通信协议。(DL/T701—2012,7.11)3.2现场总线控制系统fieldbuscontrolsystem,FCS利用现场总线技术,把现场测量、控制设备连接成网络系统,按公开、规范的通信协议,在现场测量、控制设备之间,以及这些设备与监控计算机(或DCS控制站)之间,实现双向数据传输和信息交换,构成由现场总线测量、控制设备集成的自治式控制系统,和/或由现场总线测量、控制设备与监控计算机(或DCS控制站)结合在一起构成一个完整控制系统,并可通过现场总线网络对现场测量、控制设备进行实时诊断、维护的系统。(DL/T701—2012,7.12)3.3过程现场总线processfieldBus,PROFIBUSPROFIBUS是IEC61158的组成部分,分类Type3,GB/T20540与其等效。其主要包括PROFIBUSPA、PROFIBUSDP,其中PROFIBUSDP数据传输速率9.6Kb/s~12Mb/s,PROFIBUSPA传输速率为31.25Kb/s。3.4基金会现场总线foundationfieldbus,FFFF是IEC61158的组成部分,分类Type1、Type5和Type9,Type9是Type1的子集。其主要包括H1和HSE,其中H1的传输速率为31.25Kb/s,HSE传输速率为100Mb/s。DL/T1212—201323.5现场总线设备fieldbusdevice连接在现场总线通信网络上的各类现场总线仪表,现场总线执行设备,通信组件、连接件等。3.6缩略语DP:PROFIBUSDPPA:PROFIBUSPAFFH1:FoundationFieldbusH1GSD:GenericStationDescriptionEDDL:ElectronicsDeviceDescriptionLanguageDTM:DeviceTypeManager4现场总线设备安装4.1一般要求4.1.1现场总线设备应选择经过国际现场总线组织授权机构认证的设备,协议版本应统一。4.1.2现场总线设备地址、通信速率、控制模式应设置正确,现场总线设备地址设定时需注意数据格式16进制和10进制的区分。4.1.3采用现场总线技术的控制系统组态配置中,使用的设备描述文件(EDDL或GSD或DTM)应与该设备相匹配。4.1.4现场总线设备中的电气设备、电气线路,以及电气防爆和接地工程的施工,在本规范内未作规定的部分,应符合GB50254中的有关规定。4.1.5现场总线设备安装应具备下列条件:a)设计施工图纸、有关技术文件及必要的仪表安装使用说明书已齐全。b)施工图纸已经过会审。c)已经过技术交底和必要的技术培训等技术准备工作。d)施工现场已具备仪表工程的施工条件。e)各种类型现场总线设备安装前应通过专业测试平台的连接试验。4.1.6现场总线设备标志牌上的文字及线缆进出口编号等应书写正确、清楚。4.1.7为避免油、水及灰尘进入接线盒内,现场总线设备上进出线的引入口不应朝上,否则,应采取密封措施。4.1.8现场总线设备安装前应外观完整、附件齐全,并按设计规定检查其型号、规格及材质。4.1.9现场总线设备安装时不应撞击及振动,安装后应牢固、平整。4.1.10设备的接线应符合下列规定:a)接线前应确认设备总线类型及总线电缆类型。b)剥绝缘层时不应损伤线芯和屏蔽层。c)连接处应均匀牢固、导电良好。d)锡焊时应使用无腐蚀性焊药。e)电缆(线)与端子的连接处应固定牢固,并留有适当的余度。f)接线应正确,布置应美观。4.1.11现场总线设备安装除应遵循本标准的要求外,还应按现行的GB50254和DL/T5182的规定执行。4.2现场总线仪表4.2.1现场总线仪表的安装应符合DL/T5182的相关要求。DL/T1212—201334.2.2现场总线仪表应综合考虑网段划分、地理位置和电缆敷设距离进行安装。4.2.3现场总线仪表的安装应严禁电缆连接时形成易折断的折弯。4.2.4现场总线仪表的安装应尽量避开静电干扰和电磁干扰,当无法避开时,应采取可靠的抗静电干扰、电磁干扰的措施。4.2.5现场总线仪表的安装应采取适应现场环境的防护措施。4.2.6安装位置应符合下列规定:a)照明充足,操作和维修方便;不宜安装在振动、潮湿、易受机械损伤、有强磁场干扰、高温温度变化剧烈和有腐蚀性气体的地方。b)仪表的中心距地面的高度宜为1.2m~1.5m。带有就地显示屏的仪表应安装在手动操作阀门时便于观察仪表示值的位置。4.3现场总线执行设备4.3.1变频器4.3.1.1变频器应是符合国际和国内电磁兼容标准、技术成熟、谐波抑制措施完善的设备,并具备现场总线通信接口。4.3.1.2现场总线相关通信柜应远离变频器柜。4.3.1.3变频器动力电源与现场总线控制电源应由不同的电源系统供电。4.3.1.4变频器前后应设置感性滤波装置。4.3.1.5变频器至电机的电缆应采用变频专用电缆。4.3.1.6接地电阻应符合变频器产品要求。4.3.1.7DP电缆屏蔽层应连接至屏蔽地。4.3.2执行机构和电磁阀4.3.2.1执行机构和电磁阀应是符合国际和国内电气标准、技术成熟的设备,并具备现场总线通信接口。4.3.2.2设备应固定牢固,通信电缆与供电线缆应按执行机构的设计,从不同的接线孔穿入。通信电缆穿过接线孔连接至通信接口板相应接线端子上,应按照图纸要求的线芯标号或颜色接线,不应接反。4.3.2.3通信电缆屏蔽层应压接至通信接口板相应的接线端子上。4.3.2.4对于冗余型执行机构,冗余通信电缆应按照通信接口板上的标识号,分别正确连接。4.3.2.5应按照实际要求对通信接口板上的终端电阻进行设置。当总线末尾的执行机构外部连接了有源终端电阻时,不应在通信接口板上再设置终端电阻。4.3.2.6总线地址需要在通信接口板上进行跳线、拨码设置时,应在执行机构带电前进行设置。对于冗余型执行机构,以同样方法设置地址。4.3.2.7总线地址需要通过遥控器或就地按钮进行设置时,执行机构应先带电,确保执行机构方式旋钮在“停止”或“就地”位置,再进行地址设置。对于冗余型执行机构,以同样方法设置地址。地址设置完成后,执行机构工作方式旋钮应置于“远方”位置。4.3.2.8液动执行机构的安装位置应低于调节器。当必须高于调节器时,两者间最大的高度差不应超过10m,且管路的集气处应有排气阀,靠近调节器处应有逆止阀或自动切断阀。4.3.2.9电磁阀在安装前应按安装使用说明书的规定检查线圈与阀体间的绝缘电阻。4.3.3智能马达驱动器4.3.3.1
本文标题:DLT12122013火力发电厂现场总线设备安装技术导则
链接地址:https://www.777doc.com/doc-6286950 .html