您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 质量控制/管理 > 沸石处理亚甲蓝的动态实验研究金晓英
*金晓英 卢志丽 王清萍 陈祖亮( 350007) ,、、。,2.6cm×20cm、7.0mL/min、20g、7cm、100mg/L,。,13h,27.3mg/g,30h,42.12mg/g。 DynamicExperimentalResearchofMethyleneBlueTreatmentbyZeoliteJINXiaoying LUZhili WANGQingping CHENZuliang(CollegeofChemistryandMaterial,FujianNormalUniversity Fuzhou350007)Abstract Thispaperresearchesmethyleneblueadsorptionbyusingzeoliteanddiscussestheeffectsofthespeedofflow,theinitialconcen-trations,theabsorbentdosageandtheionintensityonthedynamicadsorptionofmethyleneblue.Theadsorptionefficiencyisthebestwhenwithconditions:thecolumnsize2.6cm×20cm,velocityofflow7.0mL/min,theamountofzeolite20g,theheightofzeolitecomlumn7cm,initialconcentrationofmethyleneblue100mg/L,meanwhile,thebreakthroughtimeofmethylene13h,itsadsorptionamountofbreak-through27.3mg/g,thesaturationtimeofzeolite30handthesaturatedamountofadsorption42.12mg/g.KeyWords zeolite methyleneblue dynamicadsorption ,。、,,,、、、、、[1-4]。。,(300~500m2/g),。,。,[5],(),、、、、,。1 1.1 (Na2O·Al2O3·xSiO2·yH2O),≥55.0%,15.0%~30.0%,≤1.5%,≥20.0mg/g,(),(),(),。1.2 (),Z(:2.6cm×20cm,),722N(),GIX-9070MBE(),KQ-C(),BS224S()。1.3 (2.6cm,20cm),,(1)。,,,。1 ,2%~5%,;95%~98%,。2%,95%。*:(2006F3040);。·18· IndustrialSafetyandEnvironmentalProtection 2010364April20101.4 ,668nm,。[6-7],(1):q=∫t0v(C0-Ct)dt=QC0t-∫t0vCtdt(1),qt,mg;C0,mg/L;Ctt,mg/L;v,mL/min;∫t0vCtdtt。2 2.1 20g1660~2490μm,7cm,100mg/L5.5,7.0,8.5mL/min,,2。2 ,,,16h5h,32h20h。,,。,,,,,,,。,7.0mL/min。2.2 ,50,100,150,200mg/L,7.0mL/min20g1660~2490μm7cm,,3。3 ,,,。,,,。,,100mg/L。2.3 100mg/L,7.0mL/min,1660~2490μm,(15,20,25g),,4。4 ,,4h16h,17h32h。。,。20g。2.4 ,,。100mg/L,7.0mL/min,1660~2490μm,20g,7cm,NaNO3(1,5,10mmol/L),,5。5 ,NaNO3,,,9h5h。,();,,“”,,。,,。2.5 ,,,,,。,,。100mg/L,7.0mL/min,20g,7cm,·19·3(830~1660μm,1660~2490μm,2490~2520μm),,6。6 ,2490~2520μm830~1660μm、1660~2490μm,。1660~2490μm830~1660,1660~2490μm25h,。,1660~2490μm。2.6 ,,。100mg/L,7.0mL/min,1660~2490μm,20g,,5,6,7cm,,7。7 ,,。,,。。,。。3 (1),,、、、、,。、、、,,,,;,。(2),2.6mm×20cm,7.0mL/min,1660~2490μm,20g,7cm,100mg/L,13h,27.3mg/g,30h,42.12mg/g。[1],,,.[J].(),2006,40(12):2031-2032,2062.[2].、[M].:,1997.[3].[J].,1998,11(4):250-253.[4],..,2001,4(1):21-23.[5]XiaoyingJin.AdsorptionofmethyleneblueandorangeⅡontounmodifiedandsurfactant-modifiedzeolite[J].JournalofColloidandInterfaceSci-ence,2008,328(2):243-247.[6],,,.[J].,2007,25(4):44-46.[7],,,.[J].,2007,16(6):458-461.[8]KhattriSD,SinghMK.Colourremovalfromdyewastewaterusingsugarcanedustasanadsorbent[J].AdsorptionScience&Technology,1999,17(4):269-282. 金晓英,女,1977年生,博士,讲师,研究方向为环境修复技术。(:2009-08-19) 室外变压器的安装有地上、台上和柱子上3种安装方式。变压器的容量不超过315kV·A的可在柱上安装,容量为315kV·A以上的应在地上或者在台上安装。室外安装变压器应注意以下安全要求:(1)油浸电力变压器的安装应略有倾斜。从没有储油柜的一方向有储油柜的一方应有1%~1.5%的上升坡度,以便油箱内意外产生的气体能比较顺利地进入气体继电器。(2)变压器各部件及本体的固定必须牢固。(3)电气连接必须良好,铝导体与变压器的连接应采用钢铝过渡接头。(4)变压器的接地一般是其低压绕组中性点、外壳及其阀型避雷器三者共有的接地,变压器的工作零线应与接地线分开,工作零线不得埋入地下,接地必须良好;接地线上应有可断开的连接点。(5)变压器防爆管喷口前方不得有可燃物体。(6)变压器的一次引线和二次引线均应采用绝缘导线。(7)柱上变压器应安装平稳、牢固;腰栏应用直径4mm的镀锌铁丝缠绕4圈以上,且铁丝不得有接头,缠绕必须紧固。(8)柱上变压器底部距地面的高度不应小于2.5m,裸导体距地面高度不应小于3.5m。(10)变压器高度一般不应低于0.5m,其围栏高度不应低于1.7m,变压器的壳体距围栏不应少于1m,变压器操作面距围栏不应少于2m,围栏上应有明显标志。(11)变压器室围栏上应有“止步、高压危险!”的明显警示标志。—摘自《冶金安全》·20·
本文标题:沸石处理亚甲蓝的动态实验研究金晓英
链接地址:https://www.777doc.com/doc-6560443 .html