您好,欢迎访问三七文档
--2PARTI7200M3MAINUNITCONTENTSPage1.7200M3INVERTERMAINUNIT1.1PARTSNAMESOF7200M31.2RECEIVING1.3INSTALLATION1.4WIRING1.4.1TerminalCoverMounting/Removing1.4.2StandardWiringDiagram1.4.3MainCircuit1.4.4ControlCircuit1.5OPERATION1.5.1Pre-operationCheck1.5.2Pre-operationSetting1.5.3TestRunMethod1.5.4InverterStatusDisplayLED1.5.5DigitalOperatorDisplay1.5.6CheckPointsatTestRun1.6MAINTENANCE1.6.1PeriodicalInspection1.6.2HighVoltageTest1.7FAULTDISPLAYANDTROUBLESHOOTING1.7.1CheckingofCauses1.7.2AlarmDisplayandContents1.7.3CorrectiveActionforMotorFaults1.8SPECIFICATIONS1.8.1Specifications1.8.2Dimensions1.9OPTIONSANDPERIPHERALUNITS55678891117202021232527272828313030343537374446--3PARTII7200M3MAINUNITCONTENTSPage2.DESCRIPTIONOFDIGITALOPERATINGSECTION2.1FUNCTION/CONSTANTSETTING2.1.1DRV(Drive)ModeandPRG(Program)Mode2.1.2ConstantReadingandSetting2.1.3PrecautionsonConstantSetting2.2DIGITALOPERATOROPERATIONEXAMPLE2.3CONSTANTINITIALIZATIONANDLOCKPROTECTION2.3.1ConstantInitialization2.3.2ConstantLockProtection2.4CORRECTIVEFUNCTION2.4.1OutputFrequencyBias(Pn-23)andGain(Pn-22)2.4.2CalibrationofFrequencyMeter2.5MONITORFUNCTION2.6FUNCTION/CONSTANTLIST2.6.1AGroupFunctions(ConstantPn-00to19)2.6.2BGroupFunctions(ConstantPn-20to29)2.6.3CGroupFunctions(ConstantPn-30to59)2.7DESCRIPTIONOFFUNCTIONSANDCONSTANTS2.7.1DisplayofOperator2.7.2Run/StopProcedureSelection2.7.3V/fCharacteristicSetting2.7.4Accel/DecelTimeSetting2.7.54-StepSpeedChange2.7.6JogOperation2.7.7ElectronicThermalOverloadFunction2.7.8MultifunctionAnalogOutputMonitorSetting474848505253555556575759606262656871717273747677788081--4PARTII7200M3MAINUNITCONTENTSPage2.7.9S-CurvePatternSelection2.7.10FrequencyCommandGAIN/BIAS2.7.11OutputFrequencyLimit2.7.12DCInjectionBraking2.7.13FULL-RANGEAUTOMATICTORQUEBOOST2.7.14MOTORSTALLPREVENTIONFUNCTION2.7.15ULTIFUNCTIONCONTACTINPUTFUNCTIONSELECTION2.7.16MULTIFUNCTIONPHOTO-COUPLEROUTPUTFUNCTION2.7.17SPEEDAGREEDSIGNALOUTPUT2.7.18OVERTORQUEDETECTIONFUNCTION2.7.19CARRIERFREQUENCYSETTING2.7.20FREQUENCY/CURRENTMETERCALIBRATION2.7.21OPERATIONATMOMENTARYPOWERLOSS2.7.22AUTOMATICRESETANDRESTARTFUNCTION2.7.23FREQUENCYJUMPCONTROL2.7.24SPEEDSEARCHFUNCTION2.7.25FREQUENCYUP/DOWNFUNCTION2.7.26FUNCTIONSFORREDUCTIONOFMACHINE2.8PROTECTIONFUNCTIONANDTROUBLESHOOTING2.9WarningandSelf-DiagnosisFunctions818283848586889091929394959799100102104105107--517200M3INVERTERMAINUNITThe7200M3isanall-digitalinverterofcompactsizeandlownoise.Twotypesofmodelsareavailable:withdigitaloperator(JNEP--13)andwithanalogoperator(JNEP--14).Usingthedigitaloperatorachievesoptimumdriveandmonitoringbychangingthecontrolconstantsetting.Themodelprovidedwiththeanalogoperatorisusedforsimpleapplicationswherenocomplicatedconstantsettingarenecessary.Freekitoperator(JNEP--15)isalsoavailableforsampleapplications.1.1PARTSNAMESOF7200M3•WithDigitaloperatorPROTECTIVECOVERTERMINALCOVERDIGITALOPERATOR(JNEP--13DIE-CASTCASE•Withanalogoperator•FreeKitoperatorExternaldimensionsandmountingDimensionsarethesameasMethodofanalogoperatorisAsfordigitaloperator.thesameasfordigitaloperator.ANALOGOPERATOR(JNEP--14)--61.2RECEIVINGThis7200M3hasbeenputthoroughdemandingtestsatthefactorybeforeshipment.Afterunpacking,checkforthefollowing.˙Verifythepartnumberswiththepurchaseordersheetand/orpackingslip.˙TransitdamageIfanypartof7200M3isdamagedormissing,immediatelynotifytheshipper.NAMEPLATEDATAMODELDESIGNATIONJNTABDBB0001JK---7200M3SERIESReservedVoltageInputVoltageJK:200to230VA:Three-phaseAZ:400to460VB:Single-phaseSpecificationsApplicablemax.motorOutputBD:DomesticstandardsR500:0.5HPBE:ULlistedcomponent(planning)0010:10HPOperatortypeEnclosuresandmountingsB:DigitalOperator(JNEP--13)A:Openchassistype(IECIP00)C:AnalogOperator(JNEP--14)B:Enclosed,Wall-mountedtypeD:FreeKit(JNEP--15)(NEMA-1)MODELINPUTOUTPUTSER.NO.JNTABDCB0001JK---220VCLASSINVERTERAC3PH200-23050/60HzAC3PH0-230V2KVA5ATECOELEC.&MACH.CO.,LTD.3H045D1160003INVERTERMODELINPUTSPEC.OUTPUTSPEC.SERIESNUMBER--71.3INSTALLATIONLOCATIONLocationoftheequipmentisimportanttoachieveproperperformanceandnormaloperatinglife.The7200M3unitsshouldbeinstalledinareaswherethefollowingconditionsexist.•Ambienttemperature:-10to+40°C,+14to104°F(Forenclosedtype),-10to+45ºC,+14to113ºF(Foropenchassistype)•Protectedfromrainormoisture.•Protectedfromdirectsunlight.•Protectedfromcorrosivegasesorliquids.•Freeformairbornedustormetallicparticles.•Freeformvibration.•Freeformmagneticnoise.MOUNTINGSPACEUnit:mmCAUTION:•Handlewithcaresoasnottodamagetheinverterduringtransportation•Donotholdonlythefaceplate(plasticsection)butthedie-castsection.Fig1.1MountingSpace30mm30mm100mm100mm7200M3--81.4WIRINGConnectmaincircuitandcontrolcircuitwiringsecurelyasdescrinedinthefollowing.1.4.1TerminalCoverMounting/RemovingPleaseseethe7200M3manualpage4.Forremovingterminalcover,firstremovetheoperator,thenpressthecoverindirectionof1(onbothsides)and,atthesametime,liftindirectionof2.Formounting,reversetheprocedure.Thefigurebelowshowshowtounlock(indirectionof1)andlock(indirectionof2)theribboncablebetweenthedigitaloperatorandtheinverter.Pleasesee
本文标题:7200M3
链接地址:https://www.777doc.com/doc-11156142 .html