桩基沉降计算_JGJ94-200816层住宅楼11-1层桩形状:圆形桩直径d或边长b:0.70m土层沉降计算表格桩面积Ap:0.385m2单桩竖向极限承载力3973.43KN编号桩端底土层名称Esi(Mpa)土层深度zi(m)土层厚度li(m)土重度(KN/m3)长宽比a/b深宽比zi/Bc角点平均附加应力系数αiziαiziαi-zi-1αi-1(ziαi-zi-1αi-1)/EsAiAi/Esiσc(Kpa)在荷载效应准永久组合下承台底的平均附加压力F:197190KN000000000.25000.0000.0000.0000.0000.000720.000按荷载效应准永久组合计算的假想天然地基平均附加应力P0:313Kpa11\1粉质粘土15.87.77.719.81.940.860.24011.8491.8490.1171.8490.117872.460地上层数16地下层数111\4粉砂54.819124.319.91.941.330.22282.6740.8250.0150.8250.015958.030实际承台长度Lc:35m11\5粉质粘土17.915.73.719.21.941.740.20783.2620.5890.0330.5890.0331029.070实际承台宽度Bc:18m12\2粉砂55.53321.65.919.81.942.400.17923.8710.6080.0110.6080.0111145.890承台总面积A:630.00m213\1粉质粘土19.954242.419.81.942.670.17404.1760.3050.0150.3050.0151193.410基础长宽比Lc/Bc:1.94总桩数n:49桩长L:30msum0.17400.1914.1760.1911193.41桩距Sa:3.59m是否规则布桩?是附加应力σz:217.85Mpa距径比Sa/d:5.1自重应力0.2σc:238.68Mpa长径比L/d:42.9沉降计算长度Zn判断:OK短边布桩数nb:5C0:0.101C1:1.576C2:6.356桩基等效沉降系数ψe:0.417平均压缩模量Es:21.8Mpa桩基沉降计算经验系数ψ:0.632桩基中心点沉降量S:63.04mm注:1、对于采用后注浆施工工艺的灌注桩,桩基沉降计算经验系数应根据桩端持力土层类别,乘以0.7(砂、砾、卵石)~0.8(黏性土、粉土)折减系数;2、饱和土中采用预制桩(不含复打、复压、引孔沉桩)时,应根据桩距、土质、沉桩速率和顺序等因素,乘以1.3~1.8挤土效应系数,土的渗透性低,桩距小,桩数多,沉降速率快时取大值。蓝色区域表示手填内容或选择项