您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 给排水/暖通与智能化 > 给排水专业毕业设计
1目录摘要.................................................31前言...................................................42工程概况...............................................42.1建筑设计资料..........................................42.2建筑给水排水设计资料..................................43给水系统...............................................53.1综述...................................................53.2给水方式选择...........................................53.3室内给水系统的计算.....................................53.3.1给水定额及时变化系数的确定..........................53.3.2最高日用水量的计算..................................53.3.3最高日最大时用水量的计算............................63.3.4设计秒流量的计算....................................63.3.5屋顶水箱............................................63.3.6地下室内贮水池......................................73.3.7室内所需压力计算....................................93.3.8生活给水系统水力计算................................93.3.9生活给水系统加压水泵的选择.........................123.3.10水箱安装高度的校核.................................124排水系统.............................................134.1综述..................................................134.2室内排水系统.........................................134.2.1室内排水系统参数...................................134.2.2室内排水系统计算...................................1424.2.3化粪池的计算和选择.................................184.3屋面雨水排水系统.....................................194.4小区排水..............................................214.4.1排水体制...........................................214.4.2排水管道的布置与敷设...............................214.4.3商场外排水管道的布置与敷设.........................215消防系统.............................................215.1综述.................................................215.2消火栓系统...........................................225.2.1消火栓的确定........................................225.2.2消火栓给水系统计算..................................225.3自动喷淋灭火系统......................................255.3.1确定其设置场所火灾危险等级..........................255.3.2自动喷水灭火系统的组件,配件及设施..................255.3.3基本设计数据........................................255.3.4系统组件...........................................255.3.5水力计算及作用原理.................................266泵房布置..............................................29结论....................................................29总结与体会..............................................30谢辞....................................................30参考文献................................................313摘要成都市某区欲建一栋4层的XX商场。该工程的给水排水设计主要包括生活给水设计、消防给水设计和排水设计。其中,生活给水设计包括给水方式的选择、给水管径和水泵计算和选择。本设计给水方式采用水箱和水泵联合供水的方式。消防给水包括室内外消火栓的布置、自动喷淋系统的布置与计算,消防给水管道管径的选择和水泵选型。自动喷淋系统布置各层相同。排水包括排水管道的计算和排水管道的布置,屋顶雨水排水系统,生活污水的局部处理等设计项目。雨水和污水分流排放。关键词:生活给水;自动喷淋系统;消火栓给水;建筑排水AbstractAfour-storeysupermarketnamedXXXXXXwillbebuiltinChengduCity.Thedesignmainlycontainslivingwatersupply、firewatersupplyandsprinklersystemswatersupply.Thedesignoflivingwatersupplyincludesthechoosingofwatersupply’smethod、thecalculationandchoiceofpipesandpumps.Watertankandpumpswillbeusedinlivingwatersystem.Thedesignoffirewatersupplyincludesthesettingsofindoorandoutdoorhydrants、thearrangeofsprinklersystems、thecalculationandchoiceofpipesandpumps.Thedesignofdrainageincludesthecalculationandarrangeofdrainpipes、thecalculationofrainwatersystemandthedesignofpartialtreatmentofdomesticwastewater.Rainwateranddomesticwastewaterwilltreatedseparately.Keywords:LivingWaterSupply;SprinklerSystems;WaterSupplyofHydrantSystem;BuildingDrainage41前言本设计的主要任务是进行成都市XX商场的给水排水设计。这是一栋4层大型商场。1至3层为商场和库房并带加工间,4层为餐厅和库房,屋顶设有屋顶花园。每层设男女卫生间各一个,共有洗手盆8个,小便器4个,大便器14个。建筑面积约为4408.9㎡(单层),共17635.6㎡,层高为4.5m。根据建筑物性质、用途及建筑单位要求,室内设有完善的给水排水卫生设备系统。该大楼要求消防给水安全可靠,设置独立的消火栓系统及自动喷水系统,每个消火栓内设按钮,消防时直接启动消防泵。生活水泵自动启动。本设计说明书包含建筑工程设计中的给水(生活给水,消防给水),排水(雨水,生活污水)等设计项目。主要内容包括生活给水系统的设计计算、消火栓给水系统的设计计算、喷淋系统的设计计算、生活污水排水系统的设计计算、屋面雨水排水系统的设计计算以及小区给水排水的设计计算。2工程概况2.1建筑设计资料XX商场位于成都市,是一栋四层的集餐饮和商场为一体的综合建筑,1至3层为商场和库房并带加工间,4层为餐厅和库房,屋顶设有屋顶花园。每层设男女卫生间各一个,共有洗手盆8个,小便器4个,大便器14个。建筑面积为单层4408.9㎡,共17635.6㎡,层高为4.5m。根据建筑物性质、用途及建筑单位要求,室内设有完善的给水排水卫生设备系统。该大楼要求消防给水安全可靠,设置独立的消火栓系统及自动喷水系统,每个消火栓内设按钮,消防时直接启动消防泵。生活水泵要求自动启动。管道要求全部暗敷设。2.2建筑给水排水设计资料本建筑以城市给水管网为水源,大楼北面有一条DN400的市政给水干管,接管点比该处地面低0.5m,常年资用水头为280Kpa,城市管网不允许直接抽水。本地区建有生活污水处理厂,城市排水污(废)水、雨水分流制排水系统。本建筑西侧有DN600的市政排水管道(管底标高:-1.50m)和雨水管(管底标高:-2.00m)。53给水系统3.1综述建筑给水系统是供应建筑内部和小区范围内的生活用水、生产用水、消防用水等一系列工程设施的组合。本章节主要包括了给水方式的比较选择、管材选择、给水管网的计算、布置等相关设计项目。3.2给水方式选择根据本设计的实际情况,楼层较少,对供水的稳定性要求高,故采用设贮水池、水泵、水箱的给水方式。这种方式适用于室外给水管网水压经常性低于室内给水管网所需水压,室内用水量比较均匀的情况。这种供水方式的优点是供水安全可靠,水泵、水箱可互相配合运行,水泵向水箱充水,使水泵可在高效段运行,供水不受外界水压和水量波动的影响[1]。根据设计资料,已知室外给水管网常年可保证的工作压力为280kpa,故室内给水拟用水泵水箱联合供水方式,设屋顶水箱,采用上行下给供水方式。因为市政给水部门不允许从市政管网直接抽水,故在建筑物的地下室内设贮水池。3.3室内给水系统的计算3.3.1给水定额及时变化系数的确定按建筑物的性质和室内卫生设备之完善程度,查阅参考文献[2],商场选用每平方米营业厅每日最高日生活用水定额6L,时变化系数kh=1.5[2],使用时数为12小时,总的面积为13226.72m。餐厅用水选用40L/每顾客每次,时变化系数kh=1.5[2],使用时数为12小时,每日就餐人数400人,每人按一日2餐算。未预见水量按用水量之和的15%计[3]。3.3.2最高日用水量的计算最高起用水量按公式[3]:121.15dQQQ计算。式中:Qd------最高日用水量,1Q------商场营业厅用水量,2Q------餐厅用水量。6因此1231.15613226.71.5404001.521.15192096.3192.1dQQQLm3.3.3最高日最大时用水量的计算因为未预见水量按用水最之和的15%计,所以3192.11.524/12dhhQQKmhT式中:dQ-----最高日用水量,3md;hK-----小时变化系数。3.3.4设计秒流量的计算设计秒流量按公式[3]:g
本文标题:给排水专业毕业设计
链接地址:https://www.777doc.com/doc-6490337 .html