您好,欢迎访问三七文档
当前位置:首页 > 建筑/环境 > 设计及方案 > 电气工程课程设计报告
电气工程课程设计报告(某塑料制品厂总配变电所及配电系统设计)专业:电气工程及其自动化班级:一班姓名:学号:小组成员:目录:1.设计依据与负荷计算...........................................................31.1设计依据...................................................................31.2电力负荷计算.............................................................42.变电所高压电器设备选型..................................................62.1补偿电容器选择.........................................................62.2主变压器的选择.........................................................72.3补偿后高压侧负荷计算...............................................93.短路电流计算................................................................103.1三相短路电流的计算公式(标幺值计算方法):...........103.2短路计算等效电路....................................................113.3短路电流计算..........................................................114.设备选择.......................................................................154.1高压设备选择..........................................................154.2高压设备选择列表....................................................174.3线路选择................................................................215.继电保护.......................................................................235.1高压进线的继电保护.................................................235.2各变电所进线保护....................................................245.3变压器继电保护.......................................................25设计题目3某塑料制品厂总配变电所及配电系统设计1.设计依据与负荷计算1.1设计依据一.此厂生产任务及车间组成1.本厂生产规模及产品规格年产量为万吨聚乙烯及烃塑料制品。产品品种有薄膜、单丝、管材和注射等制品。其原料来源于某石油化纤总厂。2.车间组成及布置本厂设有薄膜、单丝、管材和注射等四个车间,设备选型全部采用我国最新定型设备,此外还有辅助车间及其它设备。二.设计依据1.供用电协议。工厂与电业部门所签定的供用电协议主要内容如下:1)工厂电源从电业部门某110/10千伏变电所,用10千伏架空线引入本厂,该变电所在厂南侧1公里;2)电业部门对本厂提出的技术要求:①区域变电所10千伏配出线路定时限过流保护装置的整定时间为2.5秒,工厂“总降”不应大于2秒;②在总配电所35千伏侧进行计量;③本厂的功率因数值应在0.9以上。3)配电系统技术数据:电业部门变电所10千伏母线其短路容量为200MVA。2.多数车间为三班制,少数车间为一班或两班制。年最大负荷利用小时数为5000小时。属于三级负荷。3.气象条件1)最热月平均最高温度为35℃。2)土壤中0.7~1米深处一年中最热月平均温度为20℃。3)年雷暴日为30天。4)土壤冻结深度为1.10米。5)夏季主导风向为南风。4.地质及水文条件。根据工程地质勘探资料获悉,本厂地质构造为:1)地表面比较平坦,土壤主要成分为积土及砂质粘土,层厚为1.6~7米不等。2)地下水位一般为0.7米。3)地耐压力为20吨/平方米。1.2电力负荷计算依据相关公式exjsPKP*tan*jsjsPQcos/jsjsPS现以NO.2变电所车间负荷计算为例,计算过程如下:(在计算各车间变电所负荷合计时,同时系数分别取值:pK=0.9;qK=0.95)NO.2变电所单丝车间:有功功率:)1(jsP=dKeP=1385.00×0.6=831KW无功功率:)1(jsQ=)1(jsPtan=831×1.30=1080.3Kvar视在功率:)1(jsS=cos)1(jsP=831÷0.6=1385KV·A水泵房及其附属设备:有功功率:)2(jsP=dKeP=20.00×0.65=13KW无功功率:)2(jsQ=)2(jsPtan=13×0.75=9.75Kvar视在功率:)2(jsS=cos)2(jsP=13÷0.8=16.25KV·A对NO.2变电所总计可得:jsP=844KW,jsQ=1090.05KWjsS=22jsjsQP=2205.1090844=1378.60KV·A有pK=0.9;qK=0.95改善后的总计可得:jsP=844×0.9=759.60KWjsQ=1090.05×0.95=1035.55KWjsS=22jsjsQP=2255.103560.759=1284.27KV·A以此得出相关量填入下表:表格1全厂各车间电气设备及车间变电所负荷计算表(380V侧)序号车间或用电设备组名称设备容量(千瓦)需用系数Kx功率因数cos¢功率因数脚正切tan¢有功计算负荷(千瓦)无功计算负荷(千乏)视在计算负荷(千伏安)1)N1变电所1.00薄膜车间1400.000.600.601.33840.001117.202.00原料库30.000.250.501.737.5012.983.00生活间10.000.801.000.008.000.004.00成品库(一)25.000.300.501.737.5012.985.00成品库(二)24.000.300.501.737.2012.466.00包装材料库20.000.300.501.736.0010.387.00小计1509.00876.201165.991458.518.00乘以参差系数(即同时系数)788.581107.691359.722)N2变电所1.00单丝车间1385.000.600.601.30831.001080.302.00水泵房及其附属设备20.000.650.800.7513.009.753.00小计1405.00844.001090.051378.604.00乘以参差系数(即同时系数)759.601035.551284.273)N3变电所1.00油塑车间189.000.600.601.33113.40150.822.00管材车间880.000.350.601.33308.00409.643.00小计1069.00421.40560.46701.214.00乘以参差系数(即同时系数)379.26532.44653.704)N4变电所1.00备料复制车间138.000.600.501.7382.80143.242.00生活间10.000.801.000.008.000.003.00锻工车间3.000.801.000.002.400.004.00术型车间30.000.300.651.179.0010.535.00原料、生活间15.000.801.000.0012.000.006.00仓库15.000.300.501.174.505.277.00机修模具车间100.000.250.651.7325.0043.258.00热处理车间150.000.600.701.0290.0091.809.00铆焊车间180.000.300.501.7354.0093.4210.00小计641.00287.70387.51482.6311.00乘以参差系数(即同时系数)258.93368.13450.085)N5变电所1.00锅炉房200.000.750.750.88150.00132.002.00试验室125.000.250.501.7331.2554.063.00辅助材料库110.000.200.501.7322.0038.064.00油泵房15.000.650.800.759.757.315.00加油站10.000.650.800.756.504.886.00办公楼、招待所、食堂15.000.600.601.339.0011.977.00小计475.00228.50248.28337.428.00乘以参差系数(即同时系数)205.65235.87312.93全厂合计2657.803452.29乘以参差系数(即同时系数)全厂合计0.592392.023279.684059.422.变电所高压电器设备选型2.1补偿电容器选择依据设计要求可知,本厂功率因数应在0.9以上,而本厂的无功功率明显大于有功功率:cos=2392.02/4059.42=0.59远远小于要求的功率因数,所以需要进行无功补偿,综合考虑,设计为在低压侧进行补偿,这里选择功率因数为0.93.以对NO.1变电所进行无功补偿计算为例:Qc=21tantanjsjsPP=788.58tan(arccos0.59)-788.58tan(arccos0.93)=771.76.Kvar由计算数据可以得到要补偿的功率,实际需总补偿800kvar,故选用8个1-100-BWF6.3并联电容器进行补偿。补偿前后数值填入下表:表格2个变电所无功补偿表变电所补偿前计算需要补偿的无功(kvar)补偿方式实际补偿的无功(kvar)补偿后变压器台数及容量功率因数cosφ计算有功功率Pj(kW)计算无功功率Qj(kvar)计算视在功率Sj(kVA)计算电流Ijs(KA)功率因数cosφ计算有功功率Pj(kW)计算无功功率Q机(kvar)计算视在功率Sj(kVA)计算电流Ijs(KA)N010.58788.581107.691359.722.07771.768个BWF6.3-100-1并联电容器8000.93788.58307.69846.481.29两台S9-630/10N020.59759.601035.551284.271.95711.968个BWF6.3-100-1并联电容器8000.96759.60235.55795.281.21两台S9-630/10N030.58379.26532.44653.700.99370.874个BWF6.3-100-1并联电容器4000.94379.26132.44401.720.61一台S9-500/10N040.58258.93368.13450.080.68257.833个BWF6.3-100-1并联电容器3000.97258.9368.13267.740.41一台S9-315/10N050.66205.65235.87312.930.48148.262个BWF6.3-100-1并联电容器2000.99205.6535.87208.750.32两台S9-250/10总计0.952.2主变压器的选择由于该厂的负荷属于三级负荷,对电源的供电可靠性要求一般,同时经题目要求,以所带负荷功率为依据。(1)只装一台变压器的变电所
本文标题:电气工程课程设计报告
链接地址:https://www.777doc.com/doc-6720296 .html