您好,欢迎访问三七文档
当前位置:首页 > 临时分类 > 地基与基础分部结构验收方案
..郑州市社会福利院改扩建项目--地下室编制人:审核人:批准时间:..目录一、工程概况························································㈠、有关单位情况·····················································㈡、工程概况·····················································二、验收依据························································㈠、合同文件及设计文件···············································㈡、国家及地方质量管理规定、规范、规程及标准··························三、验收范围和内容·········································四、地基与基础分部工程验收······································㈠、基本程序··············································㈡、分部(子分部)工程过程验收········································1.施工单位自验·····································2.实体检测·············································3.组织(分部)子分部验收·············································4.人防工程验收·····································5.质监站过程监督和验收资料备案·····································五、验收计划和验收员···············································㈠、验收组织计划······································1.项目管理人员的分工···············································2.劳动力的安排·····································㈡、地基与基础分部验收人员··········································六、验收前有关地下室的工作安排······································㈠、施工单位···············································㈡、监理单位···············································㈢、业主单位··············································㈣、设计单位·················································..㈤、勘察单位··············································一、工程概况㈠、有关单位情况工程名称郑州市社会福利院改扩建项目结构类型框剪结构建设单位新蒲建设集团有限公司设计单位河南埃德莫菲建筑设计有限公司监理单位河南建基工程管理有限公司施工单位河南省惠浦建设发展有限公司勘察单位河南工程水文地质勘察院有限公司㈡、工程概况本工程位于郑州市西北角郑州市社会福利院院内(贾鲁河以东、北环路以北)。该工程地下室上部由一幢16层的老年养护楼、一幢15层的疗养楼(颐养楼)共2个单体组成,地下一层,平面以长方形展开,立面由南向北从16层~15层依次耸立。工程总建筑面积47223.00平米,其中地上43387.00平米,地下3836.00平米,最高一幢单体为老年养楼,建筑高度为59.10米。地下室基础形式为CFG复合地基、筏板基础。基础设计详见结施-02~04。基坑开挖深度一般为-4.95米及-4.45米两种,局部电梯井深坑达到-9.6米。本工程建筑抗震设防类别:重点设防类(乙类)。建筑结构抗震等级:框架二级、剪力墙为一级。人防按防护等级为核6级常6级;防化级别丙级。工程结构形式为框架剪力墙结构,地下结构主要使用C50、C30两种强度的混凝土。地下室防水采用结构自防水为主、卷材防水为辅的防水形式,其中底板、外墙、覆土顶板等采用C50P6或C30P6防水混凝土。地下室底板较厚,主要有500mm和1200mm两种形式,属大体积砼。二、验收依据㈠、合同文件及设计文件1.施工合同(包括总包、CFG桩基工程、机电工程等);2.河南埃德莫菲建筑设计有限公司和河南省人防建筑设计研究院有限公司设计..的±0.00以下施工图;3.有关地下室图纸会审纪要和设计变更资料;4.施工组织设计及分部分项工程施工方案。㈡、国家及地方质量管理规定、规范、规程及标准1.建筑工程施工质量验收统一标准(GB50300-2001);2.建筑地基与基础工程施工质量验收规范(GB50202-2002);3.混凝土结构施工质量验收规范(GB50204-2002);4.地下防水工程施工质量验收规范(GB50208-2002)。三、验收范围和内容本工程地基与基础分部工程结构结构验收包括以下子分部和分项工程:1.无支护工程(土方开挖、土方回填);2.有支护工程(包括锚杆、土钉墙);3.地基处理(水泥粉煤灰碎石桩地基);4.地下防水工程(防水混凝土、卷材防水、细部构造);5.混凝土基础(模板、钢筋、混凝土、后浇带混凝土);6.人防工程。四、地基与基础分部工程验收㈠、基本程序1.在施工单位完成施工内容并自检合格的基础基础上,施工单位对将验收的施工内容进行自评;2.报郑州市重点建设工程质量监督站进行地基与基础分部的结构实体检测报告(如实体检测出现不合格的,应由设计单位根据检测报告提出处理方案,并报质量监督机构备案。对于造成事故或有严重隐患的工程,质量监督机构应按相应程序处理);3.监理单位对验收部分核查工程资料和验收,监理单位出评估报告;4.由业主向郑州市重点建设工程质量监督站提交结构验收申请表,申请进行地基与基础分部的结构中间验收;..5.由总监理工程师或建设单位项目负责人组织勘察、设计单位及施工单位项目负责人、技术质量负责人、共同按设计要求和有关施工先是验收规范要求进行验收;6.人防工程验收;7.整个地基和基础工程部分验收在郑州市重点建设工程质量监督站的监督下完成。㈡、分部(子分部)工程过程验收1.施工单位自验分部(子分部)工程质量的验收,应在施工单位自检合格的基础上进行。施工单位确认自检合格后提出工程验收申请,工程验收时应提供下列技术文件和记录(参照《建筑工程施工质量验收检查用表实用手册》):⑴、原材料的质量合格证和质量鉴定文件主要有钢材的产品质量证明书(合格证),因本工程中混凝土采用商品混凝土,现场暂未进水泥、黄沙、石子等原材料,暂无水泥等材料质量证明书。⑵、施工记录及隐蔽工程验收文件地基与基础工程验收包括检验批质量验收记录、分项工程质量验收记录、子分部工程质量验收记录。检验批质量验收记录包括以下内容:土方开挖工程检验批质量验收记录、土方回填工程检验批质量验收记录;锚杆与土钉墙支护工程检验批质量验收记录水泥粉煤灰碎石桩地基检验批质量验收记录;防水混凝土工程检验批质量验收记录、卷材防水层检验批质量验收记录、细部构造检验批质量验收记录;模板安装工程检验批质量验收记录、模板拆除工程检验批质量验收记录、钢筋原材料检验批质量验收记录、钢筋加工检验批质量验收记录、钢筋连接检验批质量验收记录、钢筋安装检验批质量验收记录、混凝土施工检验批质量验收记录、现浇结构外观质量检验批验收记录、现浇结构尺寸偏差检验批质量验收记录。..分项工程质量验收记录包括:土方开挖、土方回填、土钉墙、防水混凝土、卷材防水层、细部构造、模板、钢筋、混凝土。子分部工程质量验收记录包括:无支护土方、有支护土方、地基处理、地下防水、混凝土基础。详见下表:分部工程子分部工程分项工程检验批地基与基础工程无支护土方土方开挖土方开挖工程检验批土方回填土方回填工程检验批有支护土方锚杆及土钉墙锚杆及土钉墙土钉墙支护工程检验批地基处理水泥粉煤灰碎石桩地基水泥粉煤灰碎石桩地基检验批地下防水防水混凝土防水混凝土工程检验批卷材防水卷材防水层检验批细部构造细部构造检验批混凝土基础模板工程模板安装工程工程模板拆除工程检验批钢筋工程钢筋原材料检验批钢筋加工检验批钢筋连接检验批钢筋安装检验批混凝土工程混凝土施工检验批现浇结构外观及尺寸偏差质量检验批⑶、检测试验及见证取样文件主要包括钢材原材料力学检测报告、钢筋连接接头检验报告、混凝土强度检测报告、混凝土杭渗检测报告等。⑷、其他必须提供的文件或记录。..2.实体检测主要包括保护层厚度、混凝土强度。3.组织(分部)子分部验收分部(子分部)工程验收应由总监理工程师或建筑单位项目负责人组织勘察、设计单位及施工单位的项目负责人、技术质量负责人、共同按设计要求和本规范及其他有关规定进行。⑴、分项工程的质量验收应分别按主控项目和一般项目验收;⑵、隐蔽工程应在施工单位自检合格后,于隐蔽前通知有关人员检查验收,并形成之间验收文件;⑶、分部(子分部)工程的验收,应在分项工程通过验收的基础上,对必要部位进行见证验收。⑷、主控项目必须符合验收标准规定,发现问题应立即处理直至符合要求,一般项目应有80%合格。混凝土试件强度评定不合格或对试件的代表性有怀疑时,应采用钻芯取样,检测结果符合设计要求可按合格验收。⑸、观感质量验收包括以下内容:①、地下室干净、整洁、无杂物②、地下室结构外观尺寸横平坚直、接槎平顺、结构棱角鲜明③、地下室混凝土结构表面无蜂窝麻面、光滑、表面着色统一④、地下室结构楼板或墙面无明显裂缝⑤、地下室干燥、墙面和地面无湿迹⑥、地下室照明充分⑦、结构的金属预埋件经过防锈处理4.人防工程验收5.质监站过程监督和验收资料备案五、验收计划和验收人员㈠、验收组织计划..1.项目管理人员的分工我公司作为工程总承包单位,由我公司负责完成验收前的资料整理、结构修补、结构实测实量、测量放线、地下室除湿和分包单位协调等工作。我公司已经高度重视,并把相关工作落实到人。人员分工详见下表:序号主管工作责任人详细事务1验收总协调赵世亮总体协调、人员分工、验收进度控制、报公司有关领导2技术工作吕新合技术资料收集整理、验收和施工方案编制3质量负责赵全民结构实测实量、质量自评报告、质量检测和验收的申请、对外协调(质监站、监理、人防等)4现场负责唐杰中针对地下室存在问题、负责具体施工方面人员的安排、质量安排、进度计划落实项目其他管理人员全力配合此次验收工作。2.劳动力的安排清理小组:地下室的清理工作由崔国营的人员组成,每天保证25人;机动小组:地下室的零星砼结构专门组成一个机动小组,由2个木工和2个钢筋工组成,直到零星砼结构施工完;修补小组:另外准备3个石工和5个瓦工对已完成结构进行修补;除湿小组:地下室的抽湿工作由4个普工组成一个除湿小组。进度计划安排详见:《地基与基础分部工程验收计划》附表-1。㈡、地基与基础分部验收人员根据《建筑工程施工质量验收统一标准》GB50300-2001中规定,具体人员包括:总监理工程师,建设单位项目负责人,施工单位(包括分包单位)项目负责人和技术、质量负责人;勘察、设计单位工程项目负责人;各相关单位项目相关负责人等。请相关单位提前通知各有关人员到场。..六、验收前有关地下室的工作安排㈠、施工单位我公司验收前的主要工作如下:1.完成地下室剩余结构的施工。包括过道、地下室未施工的洞口、地坑、水沟、排风口、集水井盖板、水沟盖板等、零星结构混凝土施工。2.对于结构剩余模板进行拆除;对结构的螺
本文标题:地基与基础分部结构验收方案
链接地址:https://www.777doc.com/doc-8438447 .html