您好,欢迎访问三七文档
10KV/2800KVA/50HZ/168A/NORMALMEDIUMVOLTAGEACDRIVEDRIVEBYPASSCABINET1A-3A7050179-001-144A7050179-002-14::::CUSTOMER:CUSTOMERORDERNUMBER:DISTRIBUTOR:DISTRIBUTORORDERNUMBER:PROJECTORDERNUMBER:ROCKWELLAUTOMATIONORDERNUMBER:PROJECT:SERIESNUMBERUNITNUMBEREQUIPMENTDESCRIPTIONLEE&MENCHEMICAL70501797050179-003-147050179-004-14DESCRIPTIONUNITNO.1234567891011121314151617181920212223242526272829SHEETDESCRIPTION3031323334353637383940414243444546474849505152535455565758MC-X1MC-X2DRAWINGINDEXGENERALNOTESANDDEVICEDESIGNATIONSTRANSFORMERANDPOWERCELLPOWERCELLMAINCOOLINGFANFORTRANSFORMERCABINETANDPOWERCABINETAUXILIARYCOOLINGFANFORTRANSFORMERCABINETANDMAINCOOLINGFANFORPOWERCABINETPLC2,DIPLC2,DIPLC2,DOPLC2,DOPLC3,DIPLC3,DIPLC4,AIPLC5,AOCONTROLUNIT,PLC,HMI,COMMUNICATIONBOARDSCONTROLUNIT,TERMINALBLOCKP1-P9MC-X2MC-X2MC-X2TC-X3TC-X4TC-X4PLC6,DOPLC6,DORELAY,OUTPUTBYPASSWIRINGINTERCONNECTIONSBYPASSCONTROLCIRCUIT1BYPASSCONTROLCIRCUIT2BYPASSCONTROLCIRCUIT3BC-X5SINGLELINEDRAWINGPOWERCABLECONNECTIONTERMINALSFORCUSTOMERUSECONTROLPOWERSUPPLY,UPS,POWERLOSSDETECTIONSWITCHINGPOWERSUPPLIES,MVCLOSEDSIGNALCONNECTIONEMERGENCYSTOP,CABINETDOORCLOSEDDETECTION,SIGNALTODCSPANELPILOTLIGHTS,MVINTERLOCKPWMCONTROLMC-X1MC-X1MC-X1BC-X5BC-X5BC-X5UNITNO.1A1A4A4A4A4A4A4A4A4A3A1A2A-3A2A1A1A2A-3A2A-3A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A3A3A3A1A.1-100101-400401-700701-900901-10001001-11001101-1200312704807629621087.1132GENERALNOTESYCOORDINATEXCOORDINATESHEETEXAMPLE:7.04FSHEET:7;X:04;Y:FALLINTERCONNECTIONSBETWEENDRIVEINPUT,OUTPUTANDBYPASSUNITSWILLBETAGGEDWITHIDENTICALNUMBERSATEACHENDANDPREFIXEDWITHTHEDESTINATIONDESIGNATION.PCA1-PCC9:TPUXX/180-AC3PCA1-PCC9:POWERCELLNUMBERINGSPECIFICATION:TPUXX/180-AC3DEVICEDESIGNATIONSCOLOURDESIGNATIONSAC-ALTERNATINGCURRENTLV-LOWVOLTAGEMFN-MAINCOOLINGFANAFN-AUXILIARYCOOLINGFANMV-MEDIUMVOLTAGEPE-EARTHPOTENTIALVSB-VOLTAGESENSINGBOARDPC-POWERCELLCB-CIRCUITBREAKERMC-LVCONTROLCABINETTC-TRANSFORMERCABINETBC-BYPASSCABINETAMBERBLACKBLUEBROWNCLEARGREENORANGEREDWHITEYELLOWABLKBBRCGORGRWYCIRCUITORDEVICEDESIGNATEDNUMBERSLASTNUMBERUSED380VACCIRCUIT220VACCIRCUIT24VDCCIRCUITFIBER-OPTICCOMMUNICATIONSCIRCUITAI/AODODRYNODEOUTPUTTRANSFORMERTOPOWERCELLMISCFORCOMMISSIONINGUSEONLYPROVISIONFORREMOTEEMERGENCYSTOP,CUSTOMERTOSUPPLY.REMOVEJUMPERWHILEINSTALLINGREMOTEEMERGENCYSTOP.IFMORETHANONEREMOTEEMERGENCYSTOPISAPPLIED,ALLSHALLBECONNECTEDINSERIES.EMERGENCYSTOPPUSHBUTTONMUSTHAVEAMAINTAINEDCONTACT.WIRENUMBERINGFORLOWVOLTAGECIRCUITSNOTE:-UPS10KVAC,3,50HzCUSTOMERSUPPLIEDDRIVECONTROLT1LV110KVAC,3,50HzMEDIUMVOLTAGEACDRIVEATTENTION:ITISCUSTOMER'SRESPONSIBILITYTOENSURESAFEACCESSTOMEDIUMVOLTAGECELLSOFINPUT/OUTPUT/BYPASSISOLATINGSWITCH(IFUSED)WHILEPERFORMINGMAINTENANCE.ZR-YJV22-3*70-8.7/10KVZR-YJV22-3*70-8.7/10KVINPUTCIRCUITBREAKERCUSTOMERSCOPEMinimumrequirementforcableMinimumrequirementforcable220VAC,1,50HzCustomerscopeofsupply;Branchprotectionisneeded;(Minimum3kVAcapacityisrequired)BYPASSCABINETELECTRICALINTERLOCKELECTRICALINTERLOCK-QF1&(QF2,QF3)SHOULDNOTBECLOSEDTOGETHER.LV1DANGERTHEMEDIUMVOLTAGEDRIVEISONECOMPONENTINTHISSYSTEMWHICHINCLUDESANINPUTDEVICESUPPLIEDBYOTHERS.THESUPPLIEROFTHEINPUTDEVICEISRESPONSIBLEFORENSURINGTHATTHEREISSAFEACCESSTOTHEINPUT/OUTPUT/BYPASSDEVICE(IFUSED)ANDSAFEACCESSTOTHEDRIVE.MVLVT1&CONNECTIONMVPCLVCONTROLCUSTOMERSUPPLIEDGROUNDX2X1LNCONTROLSIGNAL1A2A3APEGRDTOMOTORL13L12L11X54ACONTROLSIGNALWVUBYPASS&CONNECTIONUPSTREAMCIRCUITBREAKER(CUSTOMERSCOPEOFSUPPLY)220VAC,1,50HZCONTROLSIGNALWITHBRANCHCIRCUITPROTECTION(MIMIMUM3KVACAPACITYISNEEDED)MFN1MFN3MFN4MFN2MFN5Currentoutput4-20mAFrequencyoutput4-20mAQF1NOQF2NOQF3NOQF1NCQF2NCQF3NCPRECBopen220VAC0VACLN-ClosedCB220VAC0VACLNMVopeningRemoteStopRemoteStartDrivetobypassBypasstodrive+24vDCRemoteMVclosedMVPre-closedCBWarningFaultDriverunningDrivestopReadyControlFromCustomerFromCBSpareToRemoteToCBFromRemoteEmergencystopMVClosedMVclosedMVPre-closedCBWarningFaultDriverunningDrivestopReadyRemoteControlRemoteFaultresetSpareToRemoteFromRemoteSpeedInput4-20mAAnlgInput4-20mAspareAnlgInput4-20mAspare1.4-20mAshieldedcablefromcustomerinputshallbegroundedatinverterside.2.RemoteDIinputtodriveshallbeofpulsetypewithadurationof3seconds.3.Connectionmarkedwithdottedlineshallbeincustomers'scopeofsupply.ToRemoteSpareSpareSpareSpareSpareSpareNOTE:FromRemoteBypasschoiceDrivechoiceDrivechoiceBypasschoiceSpareSpareSpareSpareModbus/RS485SpareToBypass(MOTOR)FromBypassJFEYH-35-10KVJFEYH-35-10KVL21L22L23U1V1W1abc0(A)(B)(C)a1b1c1a2b2c2a3b3c3a4b4c4a5b5c5a6b6c6a10b10c10a11b11c11a12b12c12a13b13c13a14b14c14a15b15c15a19b19c19a20b20c20a21b21c21a22b22c22a23b23c23a24b24c24a7b7c7a8b8c8a9b9c9a25b25c25a26b26c26a27b27c27a16b16c16a17b17c17a18b18c18JFEYH-35-10KVJFEYH-35-10KVJFEYH-35-10KVJFEYH-35-10KVVOLTAGESENSINGCURRENTSENSINGRVVP1*0.75BLKRVVP4*0.3RVVP4*0.3Highqualitysiliconecable0.5mm60KVDC5JZ.065.031JFEYH-35-10KVJFEYH-35-10KVJFEYH-35-10KVJFEYH-35-10KVJFEYH-35-10KVReceptacleMiniaturecircuitbreakerRedundantcontactorPowerlossdetectionUPSNote:W1,W2BVR2.5W3,W4BVR1.5MiniaturecircuitbreakerSwitchingPowerSupplyMiniaturecircuitbreakerMVClosedNote:W3,
本文标题:AB变频器电路图
链接地址:https://www.777doc.com/doc-5156295 .html